CWE-1276: Hardware Child Block Incorrectly Connected to… | Glexia
CWE-1276 (Hardware Child Block Incorrectly Connected to Parent System) weakness overview with consequences, detection methods, mitigations, related CVEs and MITRE…
Glexia's Take · Automated analysis
CWE-1276: Hardware Child Block Incorrectly Connected to Parent System
Hardware Child Block Incorrectly Connected to Parent System represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.
Executive Impact
- Confidentiality,Integrity,Availability: Varies by Context
Developer Pattern
CWE-1276 is the kind of defect developers can usually prevent with explicit validation, safer framework defaults, and tests that exercise hostile input or unsafe state transitions.
Automation confidence
high confidence from CWE-1276, 4.20.
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Official CWE Definition
CWE-1276: Hardware Child Block Incorrectly Connected to Parent System
Signals between a hardware IP and the parent system design are incorrectly connected causing security risks.
Developer And Remediation Guidance
How teams prevent and detect this weakness
Causes
- Many SoCs use hardware to partition system resources between trusted and untrusted entities. One example of this concept is the Arm TrustZone, in which the processor and all security-aware IP attempt to isolate resources based on the status of a privilege bit. This privilege bit is part of the input interface in all TrustZone-aware IP. If this privilege bit is accidentally grounded or left unconnected when the IP is instantiated, privilege escalation of all input data may occur. In the Verilog code below, the security level input to the TrustZone aware peripheral is correctly driven by an appropriate signal instead of being grounded.
- Here is a code snippet from the Ariane core module in the HACK@DAC'21 Openpiton SoC [REF-1362]. To ensure full functional correctness, developers connect the ports with names. However, in some cases developers forget to connect some of these ports to the desired signals in the parent module. These mistakes by developers can lead to incorrect functional behavior or, in some cases, introduce security vulnerabilities. In the above example from HACK@DAC'21, since interrupt signals are not properly connected, the CSR module will fail to send notifications in the event of interrupts. Consequently, critical information in CSR registers that should be flushed or modified in response to an interrupt won't be updated. These vulnerabilities can potentially result in information leakage across various privilege levels.,To address the aforementioned vulnerability, developers must follow a two-step approach. First, they should ensure that all module signals are properly connected. This can often be facilitated using automated tools, and many simulators and sanitizer tools issue warnings when a signal remains unconnected or floats. Second, it is imperative to validate that the signals connected to a module align with the specifications. In the provided example, the developer should establish the correct connection of interrupt signals from the parent module (Ariane core) to the child module (csr_regfile) [REF-1363].
Remediation
- Testing: System-level verification may be used to ensure that components are correctly connected and that design security requirements are not violated due to interactions between various IP blocks.
Detection
- Code review
- SAST
- DAST
- Focused regression tests
Mappings
Related CVEs, CWEs, and ATT&CK context
Related CWEs
ATT&CK Relevance
ATT&CK relevance is shown only when reviewed or responsibly inferred.