CVE-2026-89938: iio: chemical: atlas-sensor: use iio_trigger_poll_nested() to fix remove UAF
In the Linux kernel, the following vulnerability has been resolved:
iio: chemical: atlas-sensor: use iio_trigger_poll_nested() to fix remove UAF
The atlas driver requests its hardware data-ready IRQ with
devm_request_threaded_irq(); its threaded handler queues an irq_work,
atlas_work_handler(), that calls iio_trigger_poll(data->trig).
The IRQ is devm-managed, so free_irq() runs from the devres unwind after
atlas_remove() returns without flushing that irq_work. Once a buffer is
enabled, conversion-complete IRQs keep firing and queueing it; a pending
irq_work can therefore run after the unwind has freed atlas_data/indio_dev
and the trigger, when atlas_work_handler() derives the atlas_data pointer
via container_of() and dereferences data->trig, a use-after-free.
Call iio_trigger_poll_nested() directly from the threaded handler instead
of bouncing through irq_work. free_irq() then drains the threaded handler,
closing the window; other iio drivers with a threaded data-ready IRQ do the
same (e.g. bmi270).
This issue was found by an in-house static analysis tool.
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
cve · low confidence lookup
CVE-2026-89938 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
1CVSS vectors
3Timeline events
0ADP providers
6Source links
CVSS vector scores
1 official score
We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.