LiveActive security incident?Get immediate response
CVE Record

CVE-2026-1687: Tenda HG10 Boa Webserver formSamba command injection

A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.

HighCVSS 7.5Not KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

CVE-2026-1687 affects Tenda HG10 firmware and allows remote command injection through the Boa web interface. A public proof of concept is referenced, but the CVE is not listed in KEV and the provided sources do not confirm active exploitation. Internet-exposed or untrusted-network-accessible devices should be treated as urgent.

Executive priority

Prioritize exposed devices this week, especially any reachable from the internet. The business risk is device takeover and network foothold from a low-complexity remote flaw with public PoC material. If no vendor fix exists, containment and replacement planning are appropriate.

Technical view

The issue is a command injection in /boaform/formSamba of the Boa Webserver component. Manipulation of the serverString argument can lead to command execution. The affected version named in sources is US_HG7_HG9_HG10re_300001138_en_xpon for Tenda HG10 firmware. CVSS v2 is 7.5 with network attack vector, low complexity, and no authentication.

Likely exposure

Highest exposure is Tenda HG10 devices running the named firmware with the Boa web interface reachable from the internet, guest networks, or other untrusted segments. Internal-only devices still matter if attackers gain LAN access.

Exploitation context

Sources state the vulnerability is remotely exploitable and that public exploit material exists. There is no KEV listing and no cited evidence of active exploitation in the provided bundle. Public PoC availability increases near-term scanning and opportunistic abuse risk.

Researcher notes

Evidence comes primarily from VulDB/CVE metadata and a referenced GitHub PoC. The vulnerable function is unspecified beyond /boaform/formSamba and serverString. Vendor remediation is not identified in the supplied sources, so avoid assuming a patch exists. Do not treat this as confirmed exploited without additional evidence.

Mitigation direction

  • Check Tenda guidance for firmware updates or official mitigations.
  • Remove public internet access to the device web interface.
  • Restrict management access to trusted administrative networks only.
  • Disable unused services where vendor documentation supports doing so.
  • Consider replacement if no fixed firmware is available.

Validation and detection

  • Inventory Tenda HG10 devices and record firmware versions.
  • Identify any device running US_HG7_HG9_HG10re_300001138_en_xpon.
  • Confirm whether /boaform/formSamba is reachable from untrusted networks.
  • Review firewall, NAT, and remote-management exposure for affected devices.
  • Monitor logs for suspicious access to the Boa web interface.
Prepared
Confidence
medium
Sources
7

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-74: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cwe · medium confidence lookup

CWE-77: Command execution behavior lookup

Command injection weaknesses can lead defenders to review execution techniques and command interpreter telemetry. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2026-1687 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
High
CVSS
7.5 (2.0)
Known Exploited
No
Published

Vector: AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
6Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
7.5CVSS 2.0HighAV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR106.4Primary CVE score

Vulnerability scoring details

Base CVSS 2.0 score

7.5High
CVSS 2.0 vector shape for CVE-2026-1687Access VectorAccess ComplexityAuthenticationConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR

Access Vector
NetworkAdjacentLocal
Access Complexity
LowMediumHigh
Authentication
NoneSingleMultiple
Confidentiality Impact
CompletePartialNone
Integrity Impact
CompletePartialNone
Availability Impact
CompletePartialNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
TendaHG10US_HG7_HG9_HG10re_300001138_en_xponListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-74 · source CWE mapping

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.

CWE-77 · source CWE mapping

Improper Neutralization of Special Elements used in a Command ('Command Injection')

Improper Neutralization of Special Elements used in a Command ('Command Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.