Security readout for executives and security teams
Plain-English summary
CVE-2026-1475 is a critical SQL injection flaw in Quatuor Evaluación de Desempeño (EDD). An unauthenticated attacker could use the Id_usuario parameter to pull sensitive database information through out-of-band channels. Organizations using this application should treat exposure as urgent because the issue affects confidentiality and integrity, and the source lists all versions as affected.
Executive priority
High priority. If Quatuor EDD is in use, quickly determine whether it is externally reachable and whether sensitive HR or performance data is stored in its database. Until vendor guidance is confirmed, reduce exposure and increase monitoring.
Technical view
The vulnerability is CWE-89 out-of-band SQL injection in /evaluacion_acciones_evalua.aspx via the Id_usuario parameter. CVSS 4.0 is 9.3: network-exploitable, low complexity, no privileges, no user interaction, with high vulnerable-system confidentiality and integrity impact. The public notice identifies all versions of Quatuor EDD as affected.
Likely exposure
Exposure is likely limited to organizations running Quatuor Evaluación de Desempeño (EDD), especially if the application is reachable from untrusted networks. The source bundle states all versions are affected, but provides no CPEs or deployment details.
Exploitation context
The sources describe unauthenticated, network-based exploitation potential, but do not state active exploitation. The CVE is not marked as CISA KEV in the provided data. No exploit code or public weaponization details are included in the supplied sources.
Researcher notes
Evidence is limited to the CVE record and INCIBE advisory. The affected scope is broad: all versions of Quatuor EDD. No patch, fixed version, indicators of compromise, or confirmed exploitation are provided in the supplied sources.
Mitigation direction
- Identify whether Quatuor EDD is deployed in your environment.
- Check INCIBE and vendor guidance for patches, updates, or mitigations.
- Restrict external access to the EDD application where business allows.
- Monitor database and application logs for unusual out-of-band activity.
- Apply input validation or compensating controls only under vendor-approved guidance.
Validation and detection
- Search asset inventories for Quatuor Evaluación de Desempeño or EDD.
- Confirm whether /evaluacion_acciones_evalua.aspx is present and reachable.
- Review application exposure from internet and partner networks.
- Check logs for suspicious requests involving the Id_usuario parameter.
- Track vendor or INCIBE updates for remediation status.
Public sources used
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CWE-89: Database access and collection lookup
Injection into data stores can inform collection, data access, and exfiltration detection reviews. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
Open ATT&CK lookupDatabase behavior lookup
The CVE wording references database injection or access, so collection and exfiltration review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.
Open ATT&CK lookupCVE-2026-1475 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Critical
- CVSS
- 9.3 (4.0)
- Known Exploited
- No
- Published
Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS vector scores
1 official scoreWe collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N——Primary CVE scoreVulnerability scoring details
Base CVSS 4.0 score
9.3CriticalVector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N
Source materials
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.
