CVE-2026-1428: WellChoose|Single Sign-On Portal System - OS Command Injection

Single Sign-On Portal System developed by WellChoose has a OS Command Injection vulnerability, allowing authenticated remote attackers to inject arbitrary OS commands and execute them on the server.

HighCVSS 8.8Not KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

CVE-2026-1428 is a high-severity command injection flaw in WellChoose Single Sign-On Portal System. An attacker with valid access could run operating system commands on the server, potentially leading to data theft, system changes, or service disruption. Public sources do not state active exploitation.

Executive priority

Treat this as a high-priority identity-system risk if the product is deployed. Prioritize asset confirmation, vendor guidance review, exposure reduction, and monitoring. Urgency increases if the portal is internet-facing or accessible by many users.

Technical view

The issue is CWE-78 OS command injection. CVSS 3.1 is 8.8: network-accessible, low complexity, low privileges required, no user interaction, with high confidentiality, integrity, and availability impact. The CVE record lists WellChoose Single Sign-On Portal System, but provided version detail is limited.

Likely exposure

Exposure is most likely for organizations running WellChoose Single Sign-On Portal System where authenticated users can reach the portal over a network. Public data does not clarify exact affected versions beyond the CVE bundle’s limited version entry.

Exploitation context

Exploitation requires an authenticated remote attacker. No CISA KEV listing or cited source in the bundle confirms active exploitation. Because the affected system is an SSO portal, compromise could have broader identity and access-management consequences.

Researcher notes

The public bundle provides CVSS, CWE, authentication requirement, and TWCERT references, but does not include exploit details, affected version ranges, or a named patch. Avoid assuming broader product impact until vendor or advisory details confirm it.

Mitigation direction

  • Review the TWCERT advisory and WellChoose guidance for fixed versions or vendor instructions.
  • Restrict portal access to trusted networks or VPN where operationally feasible.
  • Review and reduce unnecessary user privileges in the SSO portal.
  • Monitor the SSO server for unusual process execution and authentication activity.
  • Prepare incident response steps for possible SSO server compromise.

Validation and detection

  • Confirm whether WellChoose Single Sign-On Portal System is deployed.
  • Identify installed version and compare it with vendor or TWCERT guidance.
  • Check whether the portal is reachable from untrusted networks.
  • Review accounts with portal access, especially low-privilege users.
  • Inspect logs for suspicious command execution indicators without running exploit tests.
Prepared
Confidence
medium
Sources
4

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-78: Command execution behavior lookup

Command injection weaknesses can lead defenders to review execution techniques and command interpreter telemetry. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2026-1428 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
High
CVSS
8.8 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
3Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
8.8CVSS 3.1HighCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H2.85.9Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

8.8High
CVSS 3.1 vector shape for CVE-2026-1428Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
WellChooseSingle Sign-On Portal System0unaffected
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-78 · source CWE mapping

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')

Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.