CVE-2025-27462: WinPVDrivers: Excessive permissions on user-exposed devices
[This CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.]
The Windows PV drivers expose various facilities to userspace. Several
of these have no security descriptor, and are therefore fully accessible
to unprivileged users. These are:
1. XenCons, CVE-2025-27462
2. XenIface, CVE-2025-27463
3. XenBus, CVE-2025-27464
Security readout for executives and security teams
Plain-English summary
CVE-2025-27462 affects Xen Windows PV drivers. The XenCons user-exposed device lacks a security descriptor, making it fully accessible to unprivileged Windows users. The business risk is serious local compromise or guest-impact potential, but the provided sources do not show remote exploitation or active abuse.
Executive priority
Treat as urgent for Xen-based Windows guest fleets, especially shared or multi-user systems. The severity is critical, but available evidence supports local exposure, not internet-remote exploitation.
Technical view
The CNA record maps CVE-2025-27462 to XenCons. The issue is CWE-276: incorrect default permissions. WinPV driver facilities exposed to userspace have no security descriptor; for XenCons this allows local, no-privilege access with high confidentiality, integrity, and availability impact per CVSS 4.0 score 9.4.
Likely exposure
Organizations running Windows guests with Xen Windows PV drivers are the known exposure set. The bundle does not identify specific driver versions, distributions, hypervisor builds, cloud platforms, or whether default installations are vulnerable beyond “Windows PV drivers”.
Exploitation context
No CISA KEV listing is present, and the provided sources do not state active exploitation. The attack vector is local and requires no privileges or user interaction per CVSS, so risk is highest where untrusted users can log into affected Windows guests.
Researcher notes
The public record links this CVE specifically to XenCons. Related WinPV permission issues are tracked separately as CVE-2025-27463 for XenIface and CVE-2025-27464 for XenBus. Evidence provided does not include exploit details, patch versions, or proof of active exploitation.
Mitigation direction
Review Xen advisory XSA-468 and vendor guidance for supported updates or workarounds.
Inventory Windows guests using Xen Windows PV drivers.
Prioritize systems with untrusted interactive users or shared administrative environments.
Restrict local access to affected Windows guests where feasible.
Monitor Xen and OS vendor channels for patched driver packages.
Validation and detection
Confirm whether Windows PV drivers are installed on Windows guest systems.
Check whether the XenCons device is present on those guests.
Compare installed driver packages against Xen advisory XSA-468 guidance.
Review local access paths for non-administrative users on exposed guests.
Track CVE-2025-27462 separately from related CVE-2025-27463 and CVE-2025-27464.
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Potential ATT&CK relevance
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
cwe · low confidence lookup
CWE-276: Exact CWE lookup
Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
1CVSS vectors
3Timeline events
1ADP providers
2Source links
SSVC decision data
CISA-ADPCISA Coordinator
Timestamp
Version
2.0.3
Exploitation: noneAutomatable: noTechnical Impact: total
CVSS vector scores
1 official score
We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.