CVE-2025-12011: CompactLogix ®, ControlLogix ®, Compact GuardLogix ® and GuardLogix ® Buffer Overflow

A denial-of-service issue exists in  5370/5570 controllers. This vulnerability could potentially allow a remote user to load an invalid project, causing the device to enter a major non-recoverable fault (MNRF).

CriticalCVSS 9.2Not KEV-listedUpdated
Glexia's TakeAutomated analysiscritical

Security readout for executives and security teams

Plain-English summary

This flaw can let an unauthenticated remote user put certain Rockwell Automation 5370/5570 controllers into a major non-recoverable fault by loading an invalid project. For operations, that means possible controller outage and process disruption, not evidence of data theft.

Executive priority

Treat as urgent for environments using these controllers in production, because successful exploitation can stop control equipment and disrupt operations. Prioritize plants where controller programming interfaces are reachable beyond tightly controlled engineering networks.

Technical view

CVE-2025-12011 is a CWE-120 buffer overflow denial-of-service vulnerability in CompactLogix 5370, Compact GuardLogix 5370, ControlLogix 5570, and GuardLogix 5570 controllers version 35.015 and earlier. CVSS 4.0 is 9.2 with network attack vector, low complexity, no privileges, and high availability impact.

Likely exposure

Exposure is likely where affected Rockwell Automation 5370 or 5570 controllers run version 35.015 or earlier and can receive remote project loads from reachable networks.

Exploitation context

The provided sources do not establish active exploitation, and CISA KEV status is false. The described outcome is operational denial of service through an invalid project causing major non-recoverable fault.

Researcher notes

Evidence is limited to the CVE record details and Rockwell advisory reference. The source bundle names affected families, versions, CWE-120, CVSS 9.2, and DoS/MNRF impact, but does not provide exploit evidence or detailed patch instructions.

Mitigation direction

  • Review Rockwell Automation advisory SD1781 for vendor remediation guidance.
  • Inventory affected controller models and firmware versions across OT sites.
  • Reduce network reachability to affected controllers until vendor guidance is applied.
  • Restrict project-loading capability to authorized engineering systems and users.

Validation and detection

  • Confirm whether deployed controllers match the listed 5370 or 5570 product families.
  • Check firmware or controller version against 35.015 and earlier.
  • Review OT network paths that could allow remote project loading.
  • Document compensating controls and remediation status per site.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-120: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2025-12011 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Critical
CVSS
9.2 (4.0)
Known Exploited
No
Published

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
3Timeline events
1ADP providers
2Source links

SSVC decision data

CISA-ADPCISA Coordinator
Timestamp
Version
2.0.3
Exploitation: noneAutomatable: yesTechnical Impact: partial

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
9.2CVSS 4.0CriticalCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:HRockwell

Vulnerability scoring details

Base CVSS 4.0 score

9.2Critical
CVSS 4.0 vector shape for CVE-2025-12011Attack VectorAttack ComplexityAttack RequirementsPrivileges RequiredUser InteractionVS ConfidentialityVS IntegrityVS AvailabilitySS ConfidentialitySS IntegritySS Availability

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Attack Requirements
NonePresent
Privileges Required
NoneLowHigh
User Interaction
NonePassiveActive
VS Confidentiality
HighLowNone
VS Integrity
HighLowNone
VS Availability
HighLowNone
SS Confidentiality
HighLowNone
SS Integrity
HighLowNone
SS Availability
HighLowNone

Vulnerability timeline

Timeline events are normalized from CVE metadata, CNA source timelines, ADP timelines, and KEV metadata when present.

  1. CVE reservedCVE Program

    The CVE ID was reserved by the assigning CNA.

  2. CVE publishedCVE Program

    The CVE record was published.

  3. CVE updatedCVE Program

    The CVE record metadata indicates this as the latest update time.

ADP provider summaries

CISA-ADPCISA ADP Vulnrichment
other:ssvc
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Rockwell AutomationCompactLogix® 5370 Compact GuardLogix® 5370 ControlLogix® 5570 GuardLogix® 557035.015 and earlierunaffected
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-120 · source CWE mapping

Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.