CVE-2024-7076: SQLi in Semtek Informatics Software's Semtek Sempos
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') vulnerability in Semtek Informatics Software Consulting Inc. Semtek Sempos allows Blind SQL Injection.
This issue affects Semtek Sempos: through 31072024.
Security readout for executives and security teams
Plain-English summary
CVE-2024-7076 is a critical blind SQL injection flaw in Semtek Sempos. An unauthenticated network attacker may be able to manipulate database queries, potentially exposing or changing sensitive business data. Public sources do not show confirmed exploitation, but the severity warrants prompt attention for any organization using Semtek Sempos through 31072024.
Executive priority
High urgency for Semtek Sempos users. The flaw can affect sensitive data confidentiality and integrity, and requires no credentials or user interaction according to CVSS. Confirm product presence immediately, reduce exposure, and follow official vendor or government guidance for remediation.
Technical view
The CVE describes CWE-89 improper neutralization in SQL commands affecting Semtek Informatics Software Consulting Inc. Semtek Sempos through 31072024. CVSS v4.0 is 9.3: network exploitable, low complexity, no privileges, no user interaction, with high confidentiality and integrity impact. Availability impact is listed as none.
Likely exposure
Exposure is limited to organizations running Semtek Sempos, especially versions through 31072024. Internet-facing deployments or systems reachable from untrusted networks carry higher business risk. The public record does not provide affected CPEs or deployment-specific indicators.
Exploitation context
The issue is described as blind SQL injection, which can allow database interrogation without direct visible output. The CVE is not listed as CISA KEV in the provided data, and no cited source confirms active exploitation. Treat as high-priority because exploitation conditions are favorable.
Researcher notes
Evidence is limited to the CVE record and government advisory references. One reference is marked broken in the provided bundle. No exploit proof, patch details, or technical endpoint details are included. Avoid assuming broader Semtek products are affected beyond Semtek Sempos through 31072024.
Mitigation direction
Identify whether Semtek Sempos is deployed and determine installed version/date.
Check Semtek and Turkish government advisory guidance for fixed versions or vendor instructions.
Prioritize isolation or access restriction for any affected internet-facing Sempos instance.
Review application and database logs for unusual query errors or abnormal access patterns.
Apply vendor-approved updates or mitigations when confirmed by official guidance.
Validation and detection
Confirm Semtek Sempos version is later than 31072024 or otherwise vendor-cleared.
Verify external exposure and restrict access where business use permits.
Review vulnerability management records for CVE-2024-7076 tracking and ownership.
Validate monitoring covers Sempos application and backend database activity.
Document compensating controls if an official fix is not yet applied.
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Potential ATT&CK relevance
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
cwe · medium confidence lookup
CWE-89: Database access and collection lookup
Injection into data stores can inform collection, data access, and exfiltration detection reviews. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
The CVE wording references database injection or access, so collection and exfiltration review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
1CVSS vectors
3Timeline events
1ADP providers
3Source links
SSVC decision data
CISA-ADPCISA Coordinator
Timestamp
Version
2.0.3
Exploitation: noneAutomatable: yesTechnical Impact: total
CVSS vector scores
1 official score
We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.
CWE-89 · source CWE mapping
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.