LiveActive security incident?Get immediate response
CVE Record

CVE-2023-36755: A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000R...

A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges.

CriticalCVSS 9.1Not KEV-listedUpdated
Glexia's TakeAutomated analysiscritical

Security readout for executives and security teams

Plain-English summary

CVE-2023-36755 affects Siemens RUGGEDCOM ROX industrial networking devices before V2.16.0. A privileged remote user using the web interface could abuse improper input handling to run operating-system commands as root. This is critical for operational environments because a compromised management plane can affect confidentiality, integrity, and availability of rugged network infrastructure.

Executive priority

Treat as urgent for OT and critical-network environments with affected devices. High privileges are required, but successful abuse provides root-level control of infrastructure devices, creating material operational and security risk.

Technical view

The flaw is CWE-77 command injection in the SCEP CA Certificate Name parameter of the affected devices' web interface. Missing server-side input sanitation allows an authenticated, privileged remote attacker to execute arbitrary code with root privileges. CVSS v3.1 is 9.1 with network attack vector, low complexity, high privileges required, no user interaction, and scope changed.

Likely exposure

Exposure is likely limited to organizations running listed Siemens RUGGEDCOM ROX models below V2.16.0 where privileged users can access the web interface. Internet exposure is not established by the supplied sources; assess management-plane reachability separately.

Exploitation context

The supplied bundle does not show CISA KEV listing or cite active exploitation. The CVSS temporal vector includes E:P, indicating proof-of-concept exploit maturity, but active exploitation should not be assumed from these sources alone.

Researcher notes

Focus validation on firmware version, affected model matching, web-interface exposure, and privileged access paths. Do not infer unauthenticated exploitability. Evidence for active exploitation is absent in the provided sources.

Mitigation direction

  • Inventory Siemens RUGGEDCOM ROX devices and record firmware versions.
  • Prioritize any listed model running firmware below V2.16.0.
  • Review Siemens SSA-146325 for official remediation and deployment guidance.
  • Upgrade affected devices to V2.16.0 or later where Siemens guidance applies.
  • Restrict privileged web-interface access according to existing management-plane policy.

Validation and detection

  • Confirm each device model matches the affected product list.
  • Verify firmware is V2.16.0 or later after remediation.
  • Check whether the web interface is reachable from untrusted networks.
  • Review privileged account access to affected device management interfaces.
  • Document remaining exceptions and vendor guidance followed.
Prepared
Confidence
high
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-77: Command execution behavior lookup

Command injection weaknesses can lead defenders to review execution techniques and command interpreter telemetry. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2023-36755 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Critical
CVSS
9.1 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
9.1CVSS 3.1CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C2.36Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

9.1Critical
CVSS 3.1 vector shape for CVE-2023-36755Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensRUGGEDCOM ROX MX5000All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX MX5000REAll versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1400All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1500All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1501All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1510All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1511All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1512All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1524All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX1536All versions < V2.16.0unknown
SiemensRUGGEDCOM ROX RX5000All versions < V2.16.0unknown
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-77 · source CWE mapping

Improper Neutralization of Special Elements used in a Command ('Command Injection')

Improper Neutralization of Special Elements used in a Command ('Command Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.