LiveActive security incident?Get immediate response
CVE Record

CVE-2023-24987: A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006).

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19809)

HighCVSS 7.8Not KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

Siemens Tecnomatix Plant Simulation before V2201.0006 can be compromised when a user opens a malicious SPP file. The flaw can let attacker-controlled code run inside the application, creating confidentiality, integrity, and availability risk for engineering workstations.

Executive priority

Treat as a high-priority workstation risk for engineering and manufacturing environments. Prioritize patching systems that open supplier, customer, or internet-delivered SPP files.

Technical view

The application has a CWE-787 out-of-bounds write while parsing specially crafted SPP files. CVSS 3.1 is 7.8 high: local attack vector, low complexity, no privileges required, user interaction required, and high impact across confidentiality, integrity, and availability.

Likely exposure

Exposure is likely limited to organizations using Siemens Tecnomatix Plant Simulation versions earlier than V2201.0006, especially users who receive or open external SPP project files.

Exploitation context

The bundle does not show CISA KEV listing or active exploitation. The CVSS vector reports proof-of-concept exploit maturity, but successful exploitation still requires a user to open a crafted SPP file locally.

Researcher notes

Key constraints are AV:L and UI:R, so exposure depends on file delivery and user opening behavior. The source bundle identifies ZDI-CAN-19809 but provides no exploit procedure, indicators, or affected CPEs.

Mitigation direction

  • Upgrade Tecnomatix Plant Simulation to V2201.0006 or later per Siemens guidance.
  • Restrict SPP files from untrusted sources until affected installations are remediated.
  • Use endpoint controls to limit code execution from engineering workstation user contexts.
  • Review Siemens advisory SSA-847261 for any environment-specific guidance.

Validation and detection

  • Inventory Tecnomatix Plant Simulation installations and record exact versions.
  • Confirm no deployed version is earlier than V2201.0006.
  • Review file-handling workflows for external or emailed SPP files.
  • Check endpoint telemetry for unusual child processes from Plant Simulation.
Prepared
Confidence
high
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-787: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2023-24987 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
High
CVSS
7.8 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
7.8CVSS 3.1HighCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C1.85.9Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

7.8High
CVSS 3.1 vector shape for CVE-2023-24987Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensTecnomatix Plant SimulationAll versions < V2201.0006unknown
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-787 · source CWE mapping

Out-of-bounds Write

Out-of-bounds Write represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.