Siemens Tecnomatix Plant Simulation before V2201.0006 can be compromised when a user opens a malicious SPP file. Successful exploitation could run attacker-controlled code with the current user’s privileges. The issue is serious, but it requires local user interaction and is not listed as known exploited in CISA KEV.
Executive priority
Prioritize remediation for engineering and manufacturing groups that rely on Plant Simulation or exchange model files externally. This is a high-impact file parsing flaw with a clear version boundary, but available evidence does not support emergency treatment as actively exploited.
Technical view
The application has an out-of-bounds write while parsing crafted SPP files, mapped to CWE-787. CVSS 3.1 is 7.8 with local attack vector, low complexity, no privileges required, and user interaction required. Impact is high for confidentiality, integrity, and availability.
Likely exposure
Organizations using Tecnomatix Plant Simulation versions earlier than V2201.0006 are exposed, especially where engineers exchange or import SPP files from partners, vendors, email, shared drives, or project repositories.
Exploitation context
The source data indicates proof-of-concept maturity in the CVSS vector, but the bundle does not provide active exploitation evidence. CISA KEV status is false. Exploitation depends on persuading a user to open a crafted SPP file.
Researcher notes
Focus validation on version exposure and SPP file trust boundaries. The public bundle does not include exploit details, indicators of compromise, or Siemens mitigations beyond the fixed-version boundary. Avoid assuming network exposure; the CVSS vector is local with required user interaction.
Mitigation direction
- Update Tecnomatix Plant Simulation to V2201.0006 or later.
- Review Siemens advisory SSA-847261 for vendor-specific guidance.
- Block or quarantine unsolicited SPP files until endpoints are updated.
- Limit SPP file exchange to trusted project channels.
- Run the application with least-privileged user accounts where feasible.
Validation and detection
- Inventory Tecnomatix Plant Simulation installations and record versions.
- Confirm all installations are V2201.0006 or later.
- Identify teams importing SPP files from external sources.
- Review endpoint controls for SPP file handling and quarantine coverage.
- Check Siemens advisory updates for revised affected-version information.
Public sources used
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CWE-787: Exact CWE lookup
Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
Open ATT&CK lookupCVE-2023-24984 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- High
- CVSS
- 7.8 (3.1)
- Known Exploited
- No
- Published
Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS vector scores
1 official scoreWe collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.
CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C1.85.9Primary CVE scoreVulnerability scoring details
Base CVSS 3.1 score
7.8HighVector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C
Source materials
- CVE List V5 sourceCVE List V5
- https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdfCVE reference
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.
Out-of-bounds Write
Out-of-bounds Write represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.