LiveActive security incident?Get immediate response
CVE Record

CVE-2023-24983: A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006).

A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted SPP file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-19805)

HighCVSS 7.8Not KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

Siemens Tecnomatix Plant Simulation can be compromised when a user opens a malicious SPP project file on an affected version. The bug can let attacker-controlled data corrupt memory and run code as the current user. This is high priority for engineering and manufacturing environments that exchange simulation files.

Executive priority

Treat this as a targeted-file risk, not an internet-wide emergency. Prioritize patching in manufacturing, engineering, and partner-facing environments where simulation files are exchanged or opened routinely.

Technical view

CVE-2023-24983 is a CWE-787 out-of-bounds write in Tecnomatix Plant Simulation versions before V2201.0006 while parsing crafted SPP files. CVSS 3.1 is 7.8 with local attack vector, no privileges required, user interaction required, and high confidentiality, integrity, and availability impact.

Likely exposure

Exposure is limited to organizations running Siemens Tecnomatix Plant Simulation before V2201.0006. Risk is highest where users open SPP files from vendors, partners, email, shared drives, or other untrusted sources.

Exploitation context

The source bundle does not show CISA KEV listing or active exploitation evidence. The CVSS temporal metric indicates proof-of-concept maturity, but exploitation still requires convincing a user or workflow to open a specially crafted SPP file.

Researcher notes

Focus validation on version confirmation, SPP file handling paths, and whether automated processing exists. Do not assume remote exposure unless the organization has a service or workflow that opens SPP files without user review.

Mitigation direction

  • Upgrade Tecnomatix Plant Simulation to V2201.0006 or later.
  • Review Siemens advisory SSA-847261 for vendor-specific remediation guidance.
  • Block or quarantine untrusted SPP files until systems are updated.
  • Limit SPP file exchange to trusted channels and scanned repositories.
  • Use endpoint controls to monitor Plant Simulation process behavior.

Validation and detection

  • Inventory Tecnomatix Plant Simulation installations and versions.
  • Confirm no installation is below V2201.0006.
  • Identify workflows where SPP files enter from external parties.
  • Review endpoint logs for unusual child processes or crashes from the application.
  • Document compensating controls for systems awaiting upgrade.
Prepared
Confidence
high
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-787: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2023-24983 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
High
CVSS
7.8 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
7.8CVSS 3.1HighCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C1.85.9Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

7.8High
CVSS 3.1 vector shape for CVE-2023-24983Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensTecnomatix Plant SimulationAll versions < V2201.0006unknown
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-787 · source CWE mapping

Out-of-bounds Write