LiveActive security incident?Get immediate response
CVE Record

CVE-2023-24565: A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (Al...

A vulnerability has been identified in Solid Edge SE2022 (All versions < V222.0MP12), Solid Edge SE2022 (All versions), Solid Edge SE2023 (All versions < V223.0Update2). The affected application contains an out of bounds read past the end of an allocated buffer while parsing a specially crafted STL file. This vulnerability could allow an attacker to disclose sensitive information. (ZDI-CAN-19428)

LowCVSS 3.3Not KEV-listedUpdated
Glexia's TakeAutomated analysislow

Security readout for executives and security teams

Plain-English summary

CVE-2023-24565 is a low-severity information disclosure issue in Siemens Solid Edge when opening a malicious STL file. An attacker would need a user to open the crafted file locally. The reported impact is limited to possible sensitive information disclosure, not code execution or system takeover.

Executive priority

Handle through normal patch management for engineering workstations, especially where third-party STL files are common. This does not appear to require emergency response unless local business workflows create high exposure to untrusted CAD files.

Technical view

Affected Solid Edge versions can read past the end of an allocated buffer while parsing specially crafted STL files. The issue is CWE-125 with CVSS 3.1 score 3.3, AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N. Siemens tracks it as ZDI-CAN-19428.

Likely exposure

Exposure is mainly engineering workstations using affected Siemens Solid Edge SE2022 or SE2023 versions and processing externally supplied STL files. Network-facing exposure is not indicated by the CVSS vector.

Exploitation context

The source bundle does not show active exploitation, and the CVE is not marked KEV. Exploitation requires user interaction: opening a specially crafted STL file in an affected local application.

Researcher notes

The affected list includes an inconsistent Solid Edge SE2022 entry stating all versions, while other entries specify fixed thresholds. Treat Siemens SSA-491245 as the authoritative source before closing remediation.

Mitigation direction

  • Inventory Solid Edge SE2022 and SE2023 installations.
  • Update SE2022 to V222.0MP12 or later where applicable.
  • Update SE2023 to V223.0Update2 or later.
  • Consult Siemens SSA-491245 for exact vendor guidance.
  • Limit opening STL files from untrusted sources.

Validation and detection

  • Confirm installed Solid Edge product and version on engineering endpoints.
  • Compare versions against Siemens affected-version ranges.
  • Check whether STL files are received from external parties.
  • Verify patch status against Siemens SSA-491245.
  • Review endpoint controls for untrusted CAD file handling.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-125: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2023-24565 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Low
CVSS
3.3 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
3.3CVSS 3.1LowCVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C1.81.4Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

3.3Low
CVSS 3.1 vector shape for CVE-2023-24565Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:L/I:N/A:N/E:P/RL:O/RC:C

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensSolid Edge SE2022All versions < V222.0MP12unknown
SiemensSolid Edge SE2022All versionsunknown
SiemensSolid Edge SE2023All versions < V223.0Update2unknown
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-125 · source CWE mapping

Out-of-bounds Read

Out-of-bounds Read represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.