LiveActive security incident?Get immediate response
CVE Record

CVE-2022-36323: Affected devices do not properly sanitize an input field.

Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.

CriticalCVSS 9.1Not KEV-listedUpdated
Glexia's TakeAutomated analysiscritical

Security readout for executives and security teams

Plain-English summary

CVE-2022-36323 is a critical Siemens industrial networking device flaw. An attacker who already has remote administrative access could abuse poor input sanitization to run code or open a root shell, potentially taking full control of affected routers or security appliances.

Executive priority

Treat as urgent for industrial environments using the listed Siemens networking devices. The flaw requires administrator privileges, but successful abuse could mean root-level control of infrastructure devices that may support operational connectivity.

Technical view

The issue is CWE-74 input neutralization failure in affected Siemens RUGGEDCOM RM1224 and SCALANCE M, MUM, S615, and SC devices. CVSS is 9.1 with network access, low complexity, high privileges, no user interaction, changed scope, and high confidentiality, integrity, and availability impact.

Likely exposure

Exposure is most relevant where affected Siemens industrial routers or cellular/security appliances are remotely administrable. The source bundle does not provide precise vulnerable firmware ranges; it lists version value “0” and unknown default status.

Exploitation context

CISA KEV status is false in the bundle, so active exploitation is not evidenced here. The CVSS temporal vector includes E:P, indicating proof-of-concept maturity, but high privileges are required.

Researcher notes

Evidence supports critical impact but not active exploitation. The bundle lacks exact vulnerable version ranges and concrete fix versions, so validation should anchor on Siemens advisories rather than inferred product coverage.

Mitigation direction

  • Review Siemens SSA-710008 and SSA-019200 for affected firmware and fixes.
  • Apply Siemens-provided updates or workarounds where applicable.
  • Restrict administrative interfaces to trusted management networks only.
  • Audit and limit administrative accounts on affected devices.
  • Monitor vendor advisories for product-specific remediation details.

Validation and detection

  • Inventory Siemens RUGGEDCOM RM1224 and listed SCALANCE devices.
  • Confirm firmware and model status against Siemens advisories.
  • Check whether remote administration is exposed beyond trusted networks.
  • Review administrative account use and recent configuration changes.
  • Verify remediation by rechecking advisory applicability after updates.
Prepared
Confidence
medium
Sources
5

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-74: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2022-36323 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Critical
CVSS
9.1 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
4Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
9.1CVSS 3.1CriticalCVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C2.36Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

9.1Critical
CVSS 3.1 vector shape for CVE-2022-36323Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensRUGGEDCOM RM1224 LTE(4G) EU0unknown
SiemensRUGGEDCOM RM1224 LTE(4G) NAM0unknown
SiemensSCALANCE M804PB0unknown
SiemensSCALANCE M812-1 ADSL-Router0unknown
SiemensSCALANCE M812-1 ADSL-Router0unknown
SiemensSCALANCE M816-1 ADSL-Router0unknown
SiemensSCALANCE M816-1 ADSL-Router0unknown
SiemensSCALANCE M826-2 SHDSL-Router0unknown
SiemensSCALANCE M874-20unknown
SiemensSCALANCE M874-30unknown
SiemensSCALANCE M876-30unknown
SiemensSCALANCE M876-3 (ROK)0unknown
SiemensSCALANCE M876-4 (EU)0unknown
SiemensSCALANCE M876-4 (NAM)0unknown
SiemensSCALANCE MUM853-1 (EU)0unknown
SiemensSCALANCE MUM856-1 (EU)0unknown
SiemensSCALANCE MUM856-1 (RoW)0unknown
SiemensSCALANCE S615 LAN-Router0unknown
SiemensSCALANCE SC622-2C0unknown
SiemensSCALANCE SC626-2C0unknown
SiemensSCALANCE SC632-2C0unknown
SiemensSCALANCE SC636-2C0unknown
SiemensSCALANCE SC642-2C0unknown
SiemensSCALANCE SC646-2C0unknown
SiemensSCALANCE W1748-1 M120unknown
SiemensSCALANCE W1748-1 M120unknown
SiemensSCALANCE W1788-1 M120unknown
SiemensSCALANCE W1788-2 EEC M120unknown
SiemensSCALANCE W1788-2 M120unknown
SiemensSCALANCE W1788-2IA M120unknown
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-74 · source CWE mapping

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.