LiveActive security incident?Get immediate response
CVE Record

CVE-2021-44544: Delta Electronics DIAEnergie (Update A)

DIAEnergie Version 1.7.5 and prior is vulnerable to multiple cross-site scripting vulnerabilities when arbitrary code is injected into the parameter “name” of the script “HandlerEnergyType.ashx”.

HighCVSS 7.5Not KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

Delta Electronics DIAEnergie 1.7.5 and earlier has cross-site scripting flaws in an energy-type handler. An unauthenticated network attacker could inject script content through the name parameter, creating integrity risk in the application. The provided sources do not show CISA KEV listing or active exploitation.

Executive priority

Treat as high priority for environments running Delta DIAEnergie, especially in energy or operational technology networks. The main business risk is unauthorized modification of application behavior or displayed content, not confirmed data theft or outage from the provided CVSS vector.

Technical view

CVE-2021-44544 is CWE-79 in DIAEnergie HandlerEnergyType.ashx, where the name parameter can receive arbitrary script content. CVSS 3.1 is 7.5 high: AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N. The source bundle identifies DIAEnergie version 1.7.5 and prior as vulnerable.

Likely exposure

Exposure is most likely where DIAEnergie web functionality is reachable from enterprise, operations, or remote-access networks. Internet-exposed deployments would carry higher concern. Confirm exact installed versions because the bundle names 1.7.5 and prior, while the affected metadata is broader.

Exploitation context

The bundle does not identify active exploitation, and kev is false. The CVSS vector indicates unauthenticated network attack potential without user interaction, but the sources do not provide exploit details or exploitation prevalence.

Researcher notes

Evidence is limited to the CVE description, CVSS vector, CWE-79 classification, affected version statement, and CISA advisory reference. Do not assume patch availability, exploit maturity, or affected configurations beyond DIAEnergie 1.7.5 and prior without vendor advisory confirmation.

Mitigation direction

  • Check Delta Electronics and CISA guidance for a fixed DIAEnergie release or official workaround.
  • Restrict DIAEnergie access to trusted administrative and operations networks only.
  • Remove any direct internet exposure for DIAEnergie interfaces.
  • Apply web input validation and output encoding where locally maintainable.
  • Monitor DIAEnergie logs for unexpected name parameter values or script-like content.

Validation and detection

  • Inventory DIAEnergie deployments and record installed versions.
  • Confirm whether any instance is version 1.7.5 or earlier.
  • Review network paths to DIAEnergie web handlers from untrusted segments.
  • Check whether HandlerEnergyType.ashx is reachable without authentication.
  • Review vendor or CISA advisory status before closing remediation.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-79: User-session and phishing behavior lookup

Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-44544 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
High
CVSS
7.5 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
7.5CVSS 3.1HighCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N3.93.6Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

7.5High
CVSS 3.1 vector shape for CVE-2021-44544Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Delta ElectronicsDIAEnergieAllListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-79 · source CWE mapping

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.