LiveActive security incident?Get immediate response
CVE Record

CVE-2021-38390: A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Ele...

A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

CVE-2021-38390 affects Delta Electronics DIAEnergie 1.7.5 and earlier. A remote unauthenticated attacker may abuse improper input validation in a web handler to manipulate database queries, with the CVE description stating possible code execution as NT SERVICE\MSSQLSERVER.

Executive priority

Treat this as high priority where DIAEnergie supports operational technology or energy management workflows. The concern is not just data access: the CVE description states possible code execution through unauthenticated database injection.

Technical view

The issue is CWE-89 blind SQL injection in /DataHandler/HandlerEnergyType.ashx through the user-controlled egyid parameter. The vulnerable code uses that input in an SQL query without proper validation. The source bundle does not provide CVSS scoring or detailed patch confirmation.

Likely exposure

Likely exposure is limited to organizations running Delta Electronics DIAEnergie 1.7.5 or earlier, especially where the DIAEnergie web application is reachable from untrusted networks. No other affected products are identified in the provided sources.

Exploitation context

The provided sources do not show CISA KEV listing or active exploitation evidence. The CVE description says exploitation is remote and unauthenticated, and may lead to arbitrary code execution in the SQL Server service context.

Researcher notes

Evidence is concise but serious: affected version range, endpoint, parameter, CWE, unauthenticated remote condition, and execution context are all stated. Missing evidence includes CVSS metrics, confirmed fixed version, exploit maturity, and detailed vendor remediation in the supplied bundle.

Mitigation direction

  • Check Delta and CISA guidance for fixed versions or vendor-approved mitigations.
  • Upgrade affected DIAEnergie deployments if vendor guidance identifies a supported fixed release.
  • Restrict DIAEnergie access to trusted management networks only.
  • Monitor database and web logs for suspicious HandlerEnergyType.ashx activity.
  • Do not expose DIAEnergie management interfaces directly to the internet.

Validation and detection

  • Inventory all Delta Electronics DIAEnergie deployments.
  • Confirm whether each deployment is version 1.7.5 or earlier.
  • Identify whether /DataHandler/HandlerEnergyType.ashx is reachable externally.
  • Review logs for abnormal requests involving HandlerEnergyType.ashx or egyid.
  • Document compensating controls around DIAEnergie network access.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-89: Database access and collection lookup

Injection into data stores can inform collection, data access, and exfiltration detection reviews. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
description · low confidence lookup

Database behavior lookup

The CVE wording references database injection or access, so collection and exfiltration review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-38390 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aDelta Electronics DIAEnergieDIAEnergie Version 1.7.5 and priorListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-89 · source CWE mapping

Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.