LiveActive security incident?Get immediate response
CVE Record

CVE-2021-34326: A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE20...

A vulnerability has been identified in JT2Go (All versions < V13.2), Solid Edge SE2021 (All Versions < SE2021MP5), Teamcenter Visualization (All versions < V13.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds write past the fixed-length heap-based buffer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13422)

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

This flaw affects Siemens engineering visualization and CAD tools when they parse PAR files. A malicious file could corrupt memory and run code inside the opened application. Business risk is highest where engineers exchange CAD files with suppliers, customers, or unmanaged external sources.

Executive priority

Treat as a high-priority engineering workstation risk if these Siemens tools are used. The issue is not listed as actively exploited in the provided sources, but file-triggered code execution can affect sensitive design environments and supply-chain file exchanges.

Technical view

The vulnerable plmxmlAdapterSE70.dll parser lacks proper validation of user-supplied PAR file data, causing an out-of-bounds write past a fixed-length heap buffer. A successful attack can execute code in the current process. The issue is classified as CWE-122 and tracked by ZDI as ZDI-CAN-13422.

Likely exposure

Organizations using JT2Go before V13.2, Teamcenter Visualization before V13.2, or Solid Edge SE2021 before SE2021MP5 may be exposed, especially on engineering workstations that open externally supplied PAR files.

Exploitation context

The sources describe code execution through malformed PAR file parsing, but do not cite active exploitation. CISA KEV status is false in the provided bundle. Exploitation appears to require the affected application to process attacker-controlled file content.

Researcher notes

Evidence is strongest for affected products, vulnerable library, bug class, and code execution impact. The bundle does not provide CVSS details, exploit availability, or detailed Siemens mitigation text beyond version thresholds and advisory links.

Mitigation direction

  • Upgrade JT2Go to V13.2 or later where applicable.
  • Upgrade Teamcenter Visualization to V13.2 or later where applicable.
  • Upgrade Solid Edge SE2021 to SE2021MP5 or later.
  • Consult Siemens advisories SSA-483182 and SSA-173615 for current vendor guidance.
  • Limit opening PAR files from untrusted external sources until patched.

Validation and detection

  • Inventory Siemens JT2Go, Teamcenter Visualization, and Solid Edge SE2021 installations.
  • Confirm installed versions meet or exceed the fixed release levels.
  • Identify engineering workflows that receive PAR files from external parties.
  • Check whether affected applications are installed on high-privilege or broadly connected workstations.
  • Document patch status and compensating controls for any remaining affected systems.
Prepared
Confidence
high
Sources
5

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-122: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-34326 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
4Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensJT2GoAll versions < V13.2Listed
SiemensSolid Edge SE2021All Versions < SE2021MP5Listed
SiemensTeamcenter VisualizationAll versions < V13.2Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-122 · source CWE mapping

Heap-based Buffer Overflow

Heap-based Buffer Overflow represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.