LiveActive security incident?Get immediate response
CVE Record

CVE-2021-34311: A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions...

A vulnerability has been identified in JT2Go (All versions < V13.2), Teamcenter Visualization (All versions < V13.2). The Mono_loader.dll library in affected applications lacks proper validation of user-supplied data when parsing J2K files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13352)

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

Siemens JT2Go and Teamcenter Visualization before V13.2 can mishandle J2K file parsing. If a user opens a malicious file, the application could write outside expected memory and potentially run attacker-controlled code as that user.

Executive priority

Treat as a targeted workstation code-execution risk for engineering environments. Prioritize upgrades where affected Siemens visualization tools handle supplier, customer, or internet-sourced files.

Technical view

Mono_loader.dll lacks proper validation of user-supplied data while parsing J2K files, causing a CWE-787 out-of-bounds write past an allocated structure. ZDI tracks this as ZDI-CAN-13352/ZDI-21-840. Affected products are Siemens JT2Go and Teamcenter Visualization versions before V13.2.

Likely exposure

Exposure is most likely on engineering or design workstations using JT2Go or Teamcenter Visualization before V13.2, especially where users receive or open external visualization files.

Exploitation context

The provided sources describe potential code execution in the current process. They do not show CISA KEV listing, active exploitation, public exploit status, or observed campaigns.

Researcher notes

The bundle lacks CVSS details and does not include exploit telemetry. The main technical signal is a file-parsing memory corruption flaw in Mono_loader.dll reachable through J2K parsing, with impact limited to the current process context.

Mitigation direction

  • Upgrade JT2Go to V13.2 or later where applicable.
  • Upgrade Teamcenter Visualization to V13.2 or later where applicable.
  • Review Siemens SSA-483182 for product-specific remediation guidance.
  • Limit opening J2K or visualization files from untrusted sources until upgraded.
  • Use least-privilege workstation accounts for users handling external files.

Validation and detection

  • Inventory JT2Go and Teamcenter Visualization installations and versions.
  • Confirm no affected installation remains below V13.2.
  • Identify teams that exchange visualization files with external parties.
  • Review endpoint controls around file handling and application execution.
  • Track Siemens and ZDI advisories for any revised guidance.
Prepared
Confidence
medium
Sources
4

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-787: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-34311 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
3Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensJT2GoAll versions < V13.2Listed
SiemensTeamcenter VisualizationAll versions < V13.2Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-787 · source CWE mapping

Out-of-bounds Write

Out-of-bounds Write represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.