LiveActive security incident?Get immediate response
CVE Record

CVE-2021-32967: Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user...

Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to add a new administrative user without being authenticated or authorized, which may allow the attacker to log in and use the device with administrative privileges.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

Delta Electronics DIAEnergie 1.7.5 and earlier has an authorization flaw that may let an unauthenticated attacker create a new administrator account. If reachable, this could give the attacker administrative access to the system without first stealing credentials.

Executive priority

Treat this as high priority where DIAEnergie supports operational or energy-management functions. Unauthorized administrator creation can undermine trust in the system and may require urgent containment if exposed.

Technical view

The CVE describes a CWE-288 authentication bypass in Delta Electronics DIAEnergie 1.7.5 and prior. The reported behavior is unauthenticated, unauthorized administrative user creation, followed by possible login with administrative privileges. The bundle does not provide CVSS, exploit details, or confirmed fixed-version information.

Likely exposure

Exposure is limited to organizations running Delta Electronics DIAEnergie version 1.7.5 or earlier. Business risk rises if the application or device management interface is reachable from untrusted networks or broadly accessible internally.

Exploitation context

The provided bundle does not show CISA KEV listing or cited evidence of active exploitation. It also does not include exploit maturity, attack complexity, or public proof-of-concept details.

Researcher notes

Evidence is concise but clear on impact: unauthenticated administrative user creation. The source bundle lacks CVSS, detailed attack surface, exploit status, and named remediation. Avoid assuming remote exploitability or a specific patch without checking the referenced advisory.

Mitigation direction

  • Identify all DIAEnergie deployments and confirm versions.
  • Consult Delta Electronics and CISA advisory guidance for supported fixes or workarounds.
  • Restrict DIAEnergie access to trusted administrative networks only.
  • Review administrative accounts and remove unauthorized users.
  • Monitor authentication and account-management activity for anomalies.

Validation and detection

  • Confirm whether any deployment runs DIAEnergie 1.7.5 or earlier.
  • Verify management interfaces are not exposed to untrusted networks.
  • Review current administrator accounts for unexpected additions.
  • Check available logs for suspicious account creation events.
  • Track remediation against vendor or CISA advisory updates.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-288: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-32967 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aDelta Electronics DIAEnergieDIAEnergie Version 1.7.5 and priorListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-288 · source CWE mapping

Authentication Bypass Using an Alternate Path or Channel

Authentication Bypass Using an Alternate Path or Channel represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.