CVE-2021-31575: In Config Manager, there is a possible command injection due to improper input validation.

In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.

CriticalCVSS 9.8Not KEV-listedUpdated
Glexia's TakeAutomated analysiscritical

Security readout for executives and security teams

Plain-English summary

CVE-2021-31575 is a critical command injection flaw in MediaTek Config Manager affecting EN7528 and EN7580 Linux SDK builds before TLM7.3.275.0-82. A successful attacker could gain remote elevated privileges without authentication or user interaction. The provided sources do not identify specific branded devices.

Executive priority

Treat this as urgent for any environment using MediaTek EN7528 or EN7580 based devices, especially internet-facing or broadly reachable infrastructure. The main business task is supply-chain confirmation: identify affected devices, obtain vendor-fixed firmware, and reduce exposure while waiting for validated updates.

Technical view

The CVE describes improper input validation in Config Manager, classified as CWE-77 command injection. MediaTek lists affected EN7528 and EN7580 Linux SDK versions below TLM7.3.275.0-82, with patch ID A20210009 and issue ID OSBNB00123234. CVSS 3.1 is 9.8 with network attack vector, low complexity, no privileges, and high confidentiality, integrity, and availability impact.

Likely exposure

Exposure is most likely in embedded or network devices built on MediaTek EN7528 or EN7580 using the vulnerable Linux SDK. The bundle does not map the SDK to specific end-user product models, so organizations need OEM, ODM, SBOM, or firmware evidence to confirm scope.

Exploitation context

The provided data does not show CISA KEV listing or active exploitation evidence. The risk remains high because the CVSS vector indicates unauthenticated, no-user-interaction network exploitation with full impact. The source description also says proximal attacker, creating ambiguity that should be resolved through vendor guidance.

Researcher notes

Do not assume all MediaTek products are affected. The source bundle names only EN7528 and EN7580 Linux SDK versions below TLM7.3.275.0-82. No exploit details, product model mapping, or active exploitation evidence are provided. The network-vector CVSS and proximal-attacker wording should be reconciled against MediaTek or OEM advisories.

Mitigation direction

  • Apply MediaTek patch ID A20210009 through the OEM or firmware supply chain.
  • Upgrade affected SDK or firmware to TLM7.3.275.0-82 or later where available.
  • Ask device vendors whether shipped firmware includes OSBNB00123234 fixes.
  • Restrict management access to affected devices until firmware status is confirmed.
  • Monitor vendor advisories for device-specific fixed firmware and deployment instructions.

Validation and detection

  • Inventory devices or firmware using MediaTek EN7528 or EN7580 chipsets.
  • Confirm Linux SDK version from vendor documentation, SBOMs, or firmware release notes.
  • Check whether firmware references patch A20210009 or issue OSBNB00123234.
  • Verify exposed management interfaces are limited to trusted networks.
  • Track remediation status by device model, firmware version, and vendor confirmation.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-77: Command execution behavior lookup

Command injection weaknesses can lead defenders to review execution techniques and command interpreter telemetry. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-31575 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Critical
CVSS
9.8 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
9.8CVSS 3.1CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H3.95.9Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

9.8Critical
CVSS 3.1 vector shape for CVE-2021-31575Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
MediaTek, Inc.EN7528, EN7580Linux SDK versions less than TLM7.3.275.0-82Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-77 · source CWE mapping

Improper Neutralization of Special Elements used in a Command ('Command Injection')

Improper Neutralization of Special Elements used in a Command ('Command Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.