CVE-2021-31344: A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded...

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), PLUSCONTROL 1st Gen (All versions), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), SIMOTICS CONNECT 400 (All versions < V1.0.0.0). ICMP echo packets with fake IP options allow sending ICMP echo reply messages to arbitrary hosts on the network. (FSMD-2021-0004)

MediumCVSS 6.9Not KEV-listedUpdated
Glexia's TakeAutomated analysismoderate

Security readout for executives and security teams

Plain-English summary

This Siemens issue can make affected embedded industrial products send ICMP echo replies to arbitrary network hosts when they receive crafted echo packets. It is not described as system takeover, but it can create misleading traffic and low integrity impact in operational networks.

Executive priority

Treat this as a moderate OT network integrity issue. Prioritize asset identification and Siemens advisory review, especially for networks where affected devices can receive ICMP from untrusted or broad internal segments.

Technical view

CVE-2021-31344 affects specified Siemens Capital Embedded AR Classic, PLUSCONTROL 1st Gen, and SIMOTICS CONNECT 400 versions. The flaw involves ICMP echo packets with fake IP options causing ICMP echo replies to arbitrary hosts. CVSS v4.0 is 6.9 with network, unauthenticated, low-complexity access and low integrity impact.

Likely exposure

Exposure is most likely in industrial or embedded environments running the listed Siemens products on networks where ICMP traffic can reach the device. Internet exposure is not stated in the sources and should not be assumed.

Exploitation context

The provided sources do not show CISA KEV listing or confirmed active exploitation. The attack surface is network-reachable ICMP handling and does not require authentication or user interaction, according to the CVSS vector.

Researcher notes

Evidence is limited to the CVE record and Siemens advisory references in the source bundle. CWE-843 is listed, but the functional description centers on malformed ICMP/IP option handling causing replies to arbitrary hosts. No exploit details or active exploitation evidence are provided.

Mitigation direction

  • Inventory the listed Siemens products and record exact firmware or software versions.
  • Check Siemens ProductCERT advisories for product-specific fixes and workarounds.
  • Update Capital Embedded AR Classic R20-11 to V2303 or later where applicable.
  • Update SIMOTICS CONNECT 400 to a non-affected Siemens-supported version where applicable.
  • For products listed as all versions affected, follow Siemens guidance before assuming a patch exists.

Validation and detection

  • Confirm whether any affected Siemens product is deployed in OT or embedded networks.
  • Verify product versions against the affected version ranges in the CVE record.
  • Review network paths where ICMP can reach these devices.
  • Check monitoring for unusual ICMP echo reply patterns involving affected assets.
  • Document advisory status, compensating controls, and planned remediation owners.
Prepared
Confidence
medium
Sources
7

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-843: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-31344 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Medium
CVSS
6.9 (4.0)
Known Exploited
No
Published

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
11Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
6.9CVSS 4.0MediumCVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:NPrimary CVE score

Vulnerability scoring details

Base CVSS 4.0 score

6.9Medium
CVSS 4.0 vector shape for CVE-2021-31344Attack VectorAttack ComplexityAttack RequirementsPrivileges RequiredUser InteractionVS ConfidentialityVS IntegrityVS AvailabilitySS ConfidentialitySS IntegritySS Availability

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Attack Requirements
NonePresent
Privileges Required
NoneLowHigh
User Interaction
NonePassiveActive
VS Confidentiality
HighLowNone
VS Integrity
HighLowNone
VS Availability
HighLowNone
SS Confidentiality
HighLowNone
SS Integrity
HighLowNone
SS Availability
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
SiemensCapital Embedded AR Classic 431-4220unknown
SiemensCapital Embedded AR Classic R20-110unknown
SiemensPLUSCONTROL 1st GenAll versionsunknown
SiemensSIMOTICS CONNECT 400All versions < V0.5.0.0unknown
SiemensSIMOTICS CONNECT 400All versions < V1.0.0.0unknown
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-843 · source CWE mapping

Access of Resource Using Incompatible Type ('Type Confusion')