CVE-2021-27408: The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to...

The affected product is vulnerable to an out-of-bounds read, which can cause information leakage leading to arbitrary code execution if chained to the out-of-bounds write vulnerability on the Welch Allyn medical device management tools (Welch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00).

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

This flaw affects multiple Welch Allyn medical device tools and monitors. It can expose memory contents and may contribute to arbitrary code execution when combined with a separate out-of-bounds write flaw. The source bundle does not provide CVSS scoring or confirmed exploitation evidence.

Executive priority

Healthcare organizations using affected Welch Allyn products should treat this as a high-priority remediation item because patient-care technology is involved and the flaw can support a more serious exploit chain. No active exploitation is cited in the provided sources.

Technical view

CVE-2021-27408 is a CWE-125 out-of-bounds read in specified Welch Allyn medical device management tools and devices. Affected versions are earlier than the fixed versions listed in the CVE description. The stated impact is information leakage, with arbitrary code execution possible only when chained with an out-of-bounds write vulnerability.

Likely exposure

Exposure is most likely in healthcare environments using Welch Allyn Service Tool, Connex NCE, SDK, Central Station, Service Monitor, CVSM, CIWS, CSM, or Spot 4400 versions below the listed fixed releases.

Exploitation context

The bundle does not show CISA KEV listing or other evidence of active exploitation. Risk depends on presence of affected versions and whether an attacker can reach or interact with the vulnerable Welch Allyn software or devices.

Researcher notes

The source bundle provides affected version thresholds and impact language, but not CVSS metrics, exploit details, or standalone exploitability. Analysis should stay focused on version exposure, network reachability, and whether related memory corruption issues are present.

Mitigation direction

  • Upgrade affected Welch Allyn products to the listed fixed versions or later.
  • Review CISA ICSMA-21-152-01 and vendor guidance for deployment-specific mitigations.
  • Prioritize clinical networks where affected tools manage patient-monitoring devices.
  • Limit access to medical device management systems to authorized administrative paths.
  • Track related out-of-bounds write issues that could increase impact.

Validation and detection

  • Inventory Welch Allyn tools and devices by product name and version.
  • Compare installed versions against the fixed-version thresholds in the CVE description.
  • Confirm vulnerable systems are not broadly reachable from user or guest networks.
  • Check vulnerability management records for CVE-2021-27408 remediation status.
  • Review change records to verify upgrades completed successfully.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-125: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-27408 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aWelch Allyn medical device management toolsWelch Allyn Service Tool: versions prior to v1.10, Welch Allyn Connex Device Integration Suite – Network Connectivity Engine (NCE): versions prior to v5.3, Welch Allyn Software Development Kit (SDK): versions prior to v3.2, Welch Allyn Connex Central Station (CS): versions prior to v1.8.6, Welch Allyn Service Monitor: versions prior to v1.7.0.0, Welch Allyn Connex Vital Signs Monitor (CVSM): versions prior to v2.43.02, Welch Allyn Connex Integrated Wall System (CIWS): versions prior to v2.43.02, Welch Allyn Connex Spot Monitor (CSM): versions prior to v1.52, Welch Allyn Spot Vital Signs 4400 Device (Spot 4400) / Welch Allyn Spot 4400 Vital Signs Extended Care Device: versions prior to v1.11.00Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-125 · source CWE mapping

Out-of-bounds Read

Out-of-bounds Read represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.