LiveActive security incident?Get immediate response
CVE Record

CVE-2021-23847: Unauthenticated Information Extraction Vulnerability

A Missing Authentication in Critical Function in Bosch IP cameras allows an unauthenticated remote attacker to extract sensitive information or change settings of the camera by sending crafted requests to the device. Only devices of the CPP6, CPP7 and CPP7.3 family with firmware 7.70, 7.72, and 7.80 prior to B128 are affected by this vulnerability. Versions 7.62 or lower and INTEOX cameras are not affected.

CriticalCVSS 9.8Not KEV-listedUpdated
Glexia's TakeAutomated analysiscritical

Security readout for executives and security teams

Plain-English summary

Some Bosch IP cameras can be reached remotely without required authentication, allowing sensitive information extraction or settings changes. The issue is critical because exploitation requires no login or user interaction, but the provided sources do not show confirmed active exploitation.

Executive priority

Treat as urgent for internet-exposed or broadly reachable Bosch camera fleets. The business risk is unauthorized access to camera information and settings, potentially affecting surveillance integrity and operational trust.

Technical view

CVE-2021-23847 is CWE-287 missing authentication in a critical function. Crafted remote requests can bypass expected authentication on affected Bosch CPP6, CPP7, and CPP7.3 camera firmware, with CVSS 3.1 score 9.8 and high confidentiality, integrity, and availability impact.

Likely exposure

Organizations operating Bosch IP cameras in CPP6, CPP7, or CPP7.3 families on firmware 7.70, 7.72, or 7.80 before B128. Bosch states versions 7.62 or lower and INTEOX cameras are not affected.

Exploitation context

The source bundle marks CISA KEV status as false and provides no cited evidence of active exploitation. Risk remains high because the attack is remote, unauthenticated, low complexity, and can affect device confidentiality and configuration integrity.

Researcher notes

Evidence is limited to CVE and Bosch advisory material in the bundle. Do not broaden scope beyond CPP6, CPP7, and CPP7.3 firmware 7.70, 7.72, and 7.80 before B128 without vendor confirmation.

Mitigation direction

  • Identify Bosch IP cameras and firmware versions across production networks.
  • Upgrade affected CPP6, CPP7, and CPP7.3 firmware to B128 or later where available.
  • Review Bosch PSIRT guidance before applying operational changes.
  • Restrict camera management access to trusted administrative networks.
  • Monitor camera configuration changes and unexpected remote access attempts.

Validation and detection

  • Confirm each Bosch camera family: CPP6, CPP7, CPP7.3, INTEOX, or other.
  • Record firmware versions and flag 7.70, 7.72, and 7.80 before B128.
  • Verify cameras on 7.62 or lower are not within the affected set described by Bosch.
  • Check whether affected cameras are reachable from untrusted networks.
  • Review recent configuration changes for unauthorized modifications.
Prepared
Confidence
high
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-287: Credential and account abuse lookup

Authentication and credential weaknesses can make valid-account abuse and credential telemetry useful review starting points. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-23847 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Critical
CVSS
9.8 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
9.8CVSS 3.1CriticalCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H3.95.9Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

9.8Critical
CVSS 3.1 vector shape for CVE-2021-23847Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
BoschCPP Firmware7.70, 7.72, unspecifiedListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-287 · source CWE mapping

Improper Authentication

Improper Authentication represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.