LiveActive security incident?Get immediate response
CVE Record

CVE-2021-22935: A vulnerability in Pulse Connect Secure before 9.1R12 could allow an authenticated administrator to perform...

A vulnerability in Pulse Connect Secure before 9.1R12 could allow an authenticated administrator to perform command injection via an unsanitized web parameter.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

Pulse Connect Secure before 9.1R12 had a command injection flaw in an administrative web parameter. An authenticated administrator could potentially cause the appliance to run unintended commands. The supplied sources do not provide CVSS scoring or evidence of active exploitation.

Executive priority

Treat this as a priority for any legacy Pulse Connect Secure deployment. The flaw requires admin access, but VPN appliances are high-value infrastructure, and command injection can materially increase breach impact.

Technical view

CVE-2021-22935 is CWE-77 command injection affecting Pulse Connect Secure versions before 9.1R12. The described attack path requires authenticated administrator access and involves an unsanitized web parameter. The public bundle identifies 9.1R12 as the fixed release but provides limited technical detail.

Likely exposure

Exposure is likely limited to organizations running Pulse Connect Secure before 9.1R12, especially where administrative access is reachable by many admins or from broad networks.

Exploitation context

The supplied bundle says KEV is false and includes no cited source showing active exploitation. The requirement for authenticated administrator access narrows the attacker set but does not remove risk if admin credentials are compromised.

Researcher notes

Key missing evidence includes CVSS metrics, detailed affected version ranges beyond before 9.1R12, and exploit telemetry. Avoid assuming broader Ivanti or Pulse product impact from this bundle alone.

Mitigation direction

  • Upgrade Pulse Connect Secure to 9.1R12 or later.
  • Review Pulse Secure advisory SA44858 for vendor-specific remediation guidance.
  • Limit administrative interface access to trusted networks and administrators.
  • Review administrator accounts and remove unnecessary privileges.

Validation and detection

  • Inventory Pulse Connect Secure appliances and record exact versions.
  • Confirm each appliance is running 9.1R12 or later.
  • Check vulnerability management records for CVE-2021-22935 closure.
  • Review administrative logs for unusual privileged activity.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-77: Command execution behavior lookup

Command injection weaknesses can lead defenders to review execution techniques and command interpreter telemetry. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-22935 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aPulse Connect SecureFixed in 9.1R12Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-77 · source CWE mapping

Improper Neutralization of Special Elements used in a Command ('Command Injection')

Improper Neutralization of Special Elements used in a Command ('Command Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.