LiveActive security incident?Get immediate response
CVE Record

CVE-2021-21791: An information disclosure vulnerability exists in the the way IOBit Advanced SystemCare Ultimate 14.2.0.220...

An information disclosure vulnerability exists in the the way IOBit Advanced SystemCare Ultimate 14.2.0.220 driver handles Privileged I/O read requests. A specially crafted I/O request packet (IRP) can lead to privileged reads in the context of a driver which can result in sensitive information disclosure from the kernel. The IN instruction can read two bytes from the given I/O device, potentially leaking sensitive device data to unprivileged users.

MediumCVSS 6.5Not KEV-listedUpdated
Glexia's TakeAutomated analysismoderate

Security readout for executives and security teams

Plain-English summary

CVE-2021-21791 is a local information disclosure flaw in the driver used by IOBit Advanced SystemCare Ultimate 14.2.0.220. A low-privileged user could trigger privileged I/O reads and potentially expose sensitive kernel or device data. It is not a remote takeover issue, but it matters on shared or compromised endpoints.

Executive priority

Treat this as a moderate endpoint hardening issue. It is unlikely to be the initial breach vector, but it could help an attacker already on a machine gather sensitive low-level data. Prioritize exposed shared systems and remove unnecessary consumer utility drivers from managed environments.

Technical view

The vulnerability is tied to handling of privileged I/O read requests through a crafted IRP. Talos states the IN instruction can read two bytes from a specified I/O device, leaking sensitive device data to unprivileged users. CVSS 6.5 reflects local access, low complexity, low privileges, no user interaction, changed scope, and high confidentiality impact.

Likely exposure

Exposure is limited to systems running IOBit Advanced SystemCare Ultimate 14.2.0.220 with the affected driver present. Risk is higher on multi-user Windows systems, shared workstations, or endpoints where attackers may already have low-privileged code execution.

Exploitation context

The provided sources do not show CISA KEV listing or active exploitation. The described attack context is local: a low-privileged user sends a specially crafted I/O request packet to the vulnerable driver to cause privileged reads.

Researcher notes

The source bundle identifies CWE-782 and a confidentiality-only impact. Evidence is strongest for the vulnerable version and driver behavior, but incomplete for vendor fix status, exploit availability, or affected version ranges beyond 14.2.0.220. Avoid assuming broader IOBit product exposure without vendor confirmation.

Mitigation direction

  • Inventory endpoints for IOBit Advanced SystemCare Ultimate 14.2.0.220 and its driver.
  • Check IOBit or Talos guidance for fixed versions or vendor-recommended remediation.
  • Remove or disable the affected software where it is not business-required.
  • Limit local interactive access on systems where the affected driver is present.
  • Prioritize remediation on shared, kiosk, developer, and high-value administrative endpoints.

Validation and detection

  • Confirm whether Advanced SystemCare Ultimate 14.2.0.220 is installed on Windows endpoints.
  • Verify whether the associated driver remains loaded after uninstall or upgrade attempts.
  • Review endpoint telemetry for unexpected access to the affected driver interface.
  • Validate remediation by confirming the vulnerable version and driver are absent.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-782: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-21791 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Medium
CVSS
6.5 (3.0)
Known Exploited
No
Published

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
6.5CVSS 3.0MediumCVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N24Primary CVE score

Vulnerability scoring details

Base CVSS 3.0 score

6.5Medium
CVSS 3.0 vector shape for CVE-2021-21791Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:N/A:N

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aIOBitIOBit Advanced SystemCare Ultimate 14.2.0.220Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-782 · source CWE mapping

Exposed IOCTL with Insufficient Access Control

Exposed IOCTL with Insufficient Access Control represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.