LiveActive security incident?Get immediate response
CVE Record

CVE-2021-21554: Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and, Dell Precision 7920 Rack Workst...

Dell PowerEdge R640, R740, R740XD, R840, R940, R940xa, MX740c, MX840c, and, Dell Precision 7920 Rack Workstation BIOS contain a stack-based buffer overflow vulnerability in systems with Intel Optane DC Persistent Memory installed. A local malicious user with high privileges may potentially exploit this vulnerability, leading to a denial of Service, arbitrary code execution, or information disclosure in UEFI or BIOS Preboot Environment.

MediumCVSS 6.1Not KEV-listedUpdated
Glexia's TakeAutomated analysismoderate

Security readout for executives and security teams

Plain-English summary

This vulnerability affects specific Dell PowerEdge and Precision Rack systems when Intel Optane DC Persistent Memory is installed. A local highly privileged user could trigger a BIOS/UEFI preboot flaw, potentially causing denial of service, code execution, or information disclosure. It is not described as remotely exploitable.

Executive priority

Treat this as a moderate firmware risk. It is not a broad internet-facing emergency, but affected servers should be remediated through normal firmware maintenance because successful exploitation could affect confidentiality, integrity, and availability below the operating system.

Technical view

CVE-2021-21554 is a buffer overflow in Dell BIOS/UEFI preboot handling for listed Dell platforms with Intel Optane DC Persistent Memory. The CVSS 3.1 score is 6.1 with local access, low complexity, high privileges, and user interaction required. The source bundle lists CWE-122, while the description calls it stack-based.

Likely exposure

Exposure is limited to the named Dell PowerEdge and Precision Rack models with Intel Optane DC Persistent Memory installed. Systems without that hardware condition are not shown as affected in the supplied sources.

Exploitation context

The supplied sources do not show active exploitation, and this CVE is not listed as KEV. Exploitation requires local high privileges and user interaction, so the main risk is from already-privileged insiders or post-compromise activity targeting firmware integrity.

Researcher notes

Key uncertainty is the exact fixed BIOS version because the prompt bundle provides the Dell advisory URL but not its detailed contents. Validate affected model, Optane DC Persistent Memory presence, BIOS version, and Dell’s current guidance before drawing final exposure conclusions.

Mitigation direction

  • Review Dell advisory 000187958 for model-specific BIOS guidance.
  • Apply Dell-published BIOS remediation if listed for your model.
  • Prioritize listed servers with Intel Optane DC Persistent Memory installed.
  • Restrict local administrative access to affected systems.
  • Include firmware updates in controlled maintenance and rollback planning.

Validation and detection

  • Inventory listed Dell models in production and lab environments.
  • Identify systems with Intel Optane DC Persistent Memory installed.
  • Record current BIOS versions for affected hardware.
  • Compare BIOS versions against Dell advisory guidance.
  • Confirm remediation by verifying updated BIOS versions after maintenance.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-122: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Execution behavior lookup

The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-21554 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Medium
CVSS
6.1 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
6.1CVSS 3.1MediumCVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L0.65.5Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

6.1Medium
CVSS 3.1 vector shape for CVE-2021-21554Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:L

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
DellPowerEdge BIOS Intel 15GunspecifiedListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-122 · source CWE mapping

Heap-based Buffer Overflow

Heap-based Buffer Overflow represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.