LiveActive security incident?Get immediate response
CVE Record

CVE-2021-1455: Cisco Firepower Management Center Software Cross-Site Scripting Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an unauthenticated, remote attacker to conduct a cross-site scripting (XSS) attack against a user of the interface. These vulnerabilities are due to insufficient validation of user-supplied input by the web-based management interface. An attacker could exploit these vulnerabilities by persuading a user of the interface to click a crafted link. A successful exploit could allow the attacker to execute arbitrary script code in the context of the interface or access sensitive, browser-based information.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysismoderate

Security readout for executives and security teams

Plain-English summary

CVE-2021-1455 is a set of cross-site scripting flaws in Cisco Firepower Management Center's web management interface. An attacker would need to convince an FMC user to click a crafted link. If successful, script could run in that user's browser session and may expose browser-based sensitive information.

Executive priority

Treat this as a timely hygiene issue for security management infrastructure. It is not confirmed exploited in the provided evidence, but compromise of an administrator's FMC browser session could affect sensitive security operations.

Technical view

Cisco describes insufficient validation of user-supplied input in the FMC web-based management interface. The issue is CWE-79 XSS and is remotely reachable without authentication, but exploitation depends on user interaction. The provided bundle does not include CVSS, affected version ranges, or specific fixed releases.

Likely exposure

Organizations running Cisco Firepower Management Center are potentially exposed, especially where administrators access FMC through browsers and may receive external links. The source bundle does not specify affected versions, so exposure requires checking the Cisco advisory against deployed FMC releases.

Exploitation context

No active exploitation is supported by the provided sources, and the CVE is not marked KEV. The known attack pattern is social engineering: persuading an FMC interface user to click a crafted link, leading to script execution in that interface context.

Researcher notes

The bundle supports CWE-79 XSS in Cisco FMC with unauthenticated remote reachability and required user interaction. It does not provide CVSS, vulnerable version ranges, proof-of-concept status, exploit telemetry, or named fixed releases. Avoid assuming internet exposure or exploitation without environment evidence.

Mitigation direction

  • Review Cisco's advisory for affected and fixed FMC releases.
  • Apply Cisco-recommended updates or mitigations where applicable.
  • Restrict FMC management access to trusted admin networks or VPN.
  • Train FMC administrators to avoid unsolicited FMC-related links.
  • Monitor vendor guidance for any later exploit or patch updates.

Validation and detection

  • Inventory all Cisco Firepower Management Center deployments.
  • Compare installed FMC versions against Cisco's advisory.
  • Confirm FMC management interfaces are not publicly exposed.
  • Review access paths for VPN, allowlisting, and admin-only controls.
  • Check for suspicious FMC-related links reported to administrators.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-79: User-session and phishing behavior lookup

Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2021-1455 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
CiscoCisco Firepower Management Centern/aListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-79 · source CWE mapping

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.