CVE-2020-10276: RVD#2558: Default credentials on SICK PLC allows disabling safety features

The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.

CriticalCVSS 9.8Not KEV-listedUpdated
Glexia's TakeAutomated analysiscritical

Security readout for executives and security teams

Plain-English summary

CVE-2020-10276 is a critical default-password issue affecting Mobile Industrial Robots MiR100 v2.8.1.1 and earlier. An attacker could alter the safety PLC program and disable emergency-stop behavior tied to object proximity. The business risk is physical safety impact, not just IT downtime.

Executive priority

Treat this as urgent for any facility using affected MiR100 robots. Prioritize safety validation, access control, and vendor-directed remediation before routine IT backlog work.

Technical view

The CVE describes CWE-798 default credentials on the SICK safety PLC used by affected MiR100 robots. CVSS 3.0 is 9.8, network exploitable, low complexity, no privileges or user interaction required. Manipulated safety PLC logic can affect laser-scanner safety behavior while navigation may continue normally.

Likely exposure

Exposure is likely limited to organizations operating MiR100 robots at v2.8.1.1 or earlier, especially where robot control networks are reachable beyond tightly controlled OT maintenance paths.

Exploitation context

The source bundle does not show CISA KEV listing or confirmed active exploitation. The issue is still serious because default credentials are easy to obtain and safety changes may be difficult to detect operationally.

Researcher notes

Evidence supports a default-credential weakness with safety-system consequences, but the provided sources do not name a specific patch level, workaround, or exploitation campaign. Avoid assuming broader MiR models are affected without vendor evidence.

Mitigation direction

  • Check Mobile Industrial Robots and SICK guidance for supported remediation or firmware direction.
  • Replace default safety PLC credentials through authorized maintenance procedures.
  • Restrict robot and PLC access to approved OT management networks only.
  • Review safety PLC programs against approved baselines.
  • Perform controlled validation of emergency-stop and proximity safety functions.

Validation and detection

  • Inventory MiR100 robots and identify firmware versions at or before v2.8.1.1.
  • Confirm whether the safety PLC still uses default credentials.
  • Compare safety PLC configuration with an approved engineering baseline.
  • Review maintenance records for unauthorized safety PLC changes.
  • Validate safety behavior in a controlled, documented safety test.
Prepared
Confidence
high
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-798: Credential and account abuse lookup

Authentication and credential weaknesses can make valid-account abuse and credential telemetry useful review starting points. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Credential and access behavior lookup

The CVE wording references authentication or credential exposure, so valid-account and credential-access review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2020-10276 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Critical
CVSS
9.8 (3.0)
Known Exploited
No
Published

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
9.8CVSS 3.0CriticalCVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H3.95.9Primary CVE score

Vulnerability scoring details

Base CVSS 3.0 score

9.8Critical
CVSS 3.0 vector shape for CVE-2020-10276Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Mobile Industrial Robots A/SMiR100v2.8.1.1 and beforeListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.