CVE-2020-10268: RVD#2550: Terminate Critical Services in KUKA controller KR C4

Critical services for operation can be terminated from windows task manager, bringing the manipulator to a halt. After this a Re-Calibration of the brakes needs to be performed. Be noted that this only can be accomplished either by a Kuka technician or by Kuka issued calibration hardware that interfaces with the manipulator furthering the delay and increasing operational costs.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

This CVE describes a KUKA KR C4 controller condition where critical robot-control services can be stopped through Windows Task Manager. The immediate business risk is production interruption: the manipulator can halt, and brake recalibration may require a KUKA technician or KUKA-issued hardware, increasing downtime and cost.

Executive priority

Prioritize sites where affected KUKA robots are production-critical or where controller OS access is broadly available. The issue may not be internet-facing, but the downtime and specialist recovery requirement can create material operational impact.

Technical view

The affected environment is listed as KUKA KR3R540, KRC4, KSS 8.5.7HF1 on Windows 7 Embedded. The source maps the issue to CWE-749, reflecting exposed dangerous functionality. The public bundle does not provide CVSS, patch details, privilege requirements, or confirmed exploit activity.

Likely exposure

Exposure is most relevant to facilities operating the listed KUKA KR C4 setup where users can access the underlying Windows environment or Task Manager. The source does not establish remote exposure, internet exposure, or broader KUKA model coverage.

Exploitation context

The bundle reports no CISA KEV listing and provides no evidence of active exploitation. The described action requires access to Windows Task Manager on the controller, but the public source does not define exact permissions, authentication boundaries, or attacker prerequisites.

Researcher notes

Evidence is thin: the CVE record and RVD issue identify the behavior and affected setup, but omit CVSS, patch status, detailed prerequisites, and safe validation guidance. Avoid assuming remote exploitability or coverage beyond the named KUKA controller environment.

Mitigation direction

  • Check KUKA guidance for affected controller service protections or updates.
  • Restrict interactive Windows access on robot controllers to authorized personnel.
  • Review local operating procedures for preventing unsafe service termination.
  • Maintain a brake recalibration recovery plan with KUKA support availability.
  • Treat controller OS access as operationally sensitive, not general workstation access.

Validation and detection

  • Inventory KR C4 controllers and confirm KSS 8.5.7HF1 or related builds.
  • Identify who can access Windows Task Manager on each controller.
  • Review controller hardening against unauthorized local service control.
  • Do not test by stopping services on production manipulators.
  • Check maintenance records for unexplained halts requiring brake recalibration.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-749: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2020-10268 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
KUKA Roboter GmbHKR3R540, KRC4, KSS8.5.7HF1, Win7_EmbeddedunspecifiedListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-749 · source CWE mapping

Exposed Dangerous Method or Function