LiveActive security incident?Get immediate response
CVE Record

CVE-2019-2431: Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Co...

Vulnerability in the Oracle Argus Safety component of Oracle Health Sciences Applications (subcomponent: Console). Supported versions that are affected are 8.1 and 8.2. Difficult to exploit vulnerability allows unauthenticated attacker with network access via HTTP to compromise Oracle Argus Safety. Successful attacks require human interaction from a person other than the attacker and while the vulnerability is in Oracle Argus Safety, attacks may significantly impact additional products. Successful attacks of this vulnerability can result in unauthorized creation, deletion or modification access to critical data or all Oracle Argus Safety accessible data. CVSS 3.0 Base Score 6.1 (Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:N).

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

CVE-2019-2431 affects Oracle Argus Safety 8.1 and 8.2. An unauthenticated network attacker could, with user interaction, cause unauthorized creation, deletion, or modification of critical Argus Safety data. Exploitation is described as difficult, but the business concern is integrity loss in a regulated safety system. Exposure is limited to organizations running Oracle Argus Safety versions 8.1 or 8.2, especially where HTTP access to the Console is reachable by untrusted networks or users can be induced to interact with malicious content. Treat as a planned remediation priority for any affected Argus Safety deployment. The main risk is integrity compromise of critical safety data, not confidentiality or availability, and the known exploitability evidence is limited in the provided sources. Mitigation focus: Review Oracle's January 2019 Critical Patch Update guidance for CVE-2019-2431.; Upgrade or patch affected Argus Safety 8.1 or 8.2 systems per Oracle guidance.; Restrict HTTP access to Argus Safety Console to trusted networks and users..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2019-2431 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
1Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Oracle CorporationArgus Safety8.1, 8.2Listed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.