Security readout for executives and security teams
CVE-2019-1782 lets a logged-in Cisco device administrator abuse certain CLI commands to run operating-system commands with elevated privileges. It is not described as remotely exploitable by an unauthenticated attacker, but it can materially increase damage from a compromised or malicious admin account. Exposure is most likely on Cisco infrastructure running affected FXOS or NX-OS software where administrators can access the CLI. The provided bundle does not identify exact affected versions, so asset owners must validate against Cisco's advisory. Treat this as a controlled but important infrastructure risk. It requires admin-level access, lowering broad internet risk, but successful exploitation could fully compromise affected network devices and amplify insider or credential-theft incidents. Mitigation focus: Check Cisco's advisory for affected versions and fixed software guidance.; Apply vendor-supported updates where affected devices are confirmed.; Restrict CLI access to trusted administrative paths and accounts..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CWE-77: Command execution behavior lookup
Command injection weaknesses can lead defenders to review execution techniques and command interpreter telemetry. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
Open ATT&CK lookupExecution behavior lookup
The CVE wording references code or command execution, so execution technique review may help defensive triage. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.
Open ATT&CK lookupCVE-2019-1782 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Medium
- CVSS
- 6.7 (3.0)
- Known Exploited
- No
- Published
Vector: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS vector scores
1 official scoreWe collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.
CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H0.85.9Primary CVE scoreVulnerability scoring details
Base CVSS 3.0 score
6.7MediumVector: CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Source materials
- CVE List V5 sourceCVE List V5
- 20190515 Cisco FXOS and NX-OS Software Command Injection Vulnerabilities (CVE-2019-1781, CVE-2019-1782)CVE reference · vendor-advisory, x_refsource_CISCO
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.
Improper Neutralization of Special Elements used in a Command ('Command Injection')
Improper Neutralization of Special Elements used in a Command ('Command Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.