LiveActive security incident?Get immediate response
CVE Record

CVE-2019-13936: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webcl...

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in webclient of Siemens AG Polarion could allow an attacker to exploit a persistent XSS vulnerability. This issue affects: Siemens AG Polarion All versions < 19.2.

LowCVSS 3.5Not KEV-listedUpdated
Glexia's TakeAutomated analysislow

Security readout for executives and security teams

Plain-English summary

This is a stored cross-site scripting issue in Siemens Polarion before 19.2. An authenticated attacker could save malicious content that later runs in another user's browser when viewed. The published impact is limited to confidentiality, and exploitation requires user interaction.

Executive priority

Handle through normal vulnerability management unless Polarion is exposed to many untrusted authenticated users. The issue is low severity, but persistent XSS can still affect sensitive project or engineering data viewed in Polarion.

Technical view

CVE-2019-13936 is CWE-79 in the Polarion webclient. CVSS 3.1 is 3.5: network reachable, low complexity, low privileges required, user interaction required, unchanged scope, low confidentiality impact, no integrity or availability impact.

Likely exposure

Exposure is limited to Siemens Polarion deployments running versions earlier than 19.2, especially where low-privileged or less-trusted users can create content viewed by other users in the webclient.

Exploitation context

The source bundle does not show CISA KEV listing or active exploitation evidence. Public reporting describes multiple Polarion web vulnerabilities, but this CVE's vector requires authenticated access and a victim viewing stored content.

Researcher notes

Evidence supports affected range and XSS class, but the bundle does not include a Siemens advisory or detailed patch note. Avoid assuming broader product impact beyond Siemens Polarion versions before 19.2.

Mitigation direction

  • Inventory all Siemens Polarion instances and record their versions.
  • Prioritize upgrade planning for versions earlier than Polarion 19.2.
  • Check Siemens guidance before relying on compensating controls.
  • Restrict low-trust user access to content creation where practical.
  • Review stored user content for suspicious script-like entries.

Validation and detection

  • Confirm whether any Polarion instance is below version 19.2.
  • Review access controls for users allowed to create webclient content.
  • Check audit logs for unusual content edits or saved HTML/script markers.
  • Verify remediation by confirming the upgraded Polarion version.
  • Document any accepted risk for legacy Polarion deployments.
Prepared
Confidence
high
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-79: User-session and phishing behavior lookup

Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2019-13936 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Low
CVSS
3.5 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
3.5CVSS 3.1LowCVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N2.11.4Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

3.5Low
CVSS 3.1 vector shape for CVE-2019-13936Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone
Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Siemens AGPolarionAll versions < 19.2Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-79 · source CWE mapping

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.