LiveActive security incident?Get immediate response
CVE Record

CVE-2019-12681: Cisco Firepower Management Center SQL Injection Vulnerabilities

Multiple vulnerabilities in the web-based management interface of Cisco Firepower Management Center (FMC) Software could allow an authenticated, remote attacker to execute arbitrary SQL injections on an affected device. These vulnerabilities exist due to improper input validation. An attacker could exploit these vulnerabilities by sending crafted SQL queries to an affected device. A successful exploit could allow the attacker to view information that they are not authorized to view, make changes to the system that they are not authorized to make, and execute commands within the underlying operating system that may affect the availability of the device.

HighCVSS 8.8Not KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

Cisco FMC had SQL injection flaws in its web management interface. An authenticated remote user could access unauthorized information, change system data, or cause operating-system-level impact on the management device. This is high urgency where FMC is reachable by broad admin or internal user populations.

Executive priority

Treat this as a high-priority management-plane issue. It requires authenticated access, but successful exploitation could undermine a security management platform and affect confidentiality, integrity, and availability.

Technical view

CVE-2019-12681 is a CWE-89 SQL injection issue in Cisco Firepower Management Center Software caused by improper input validation. The CVSS 3.0 score is 8.8 with low attack complexity, network access, low privileges, no user interaction, and high confidentiality, integrity, and availability impact.

Likely exposure

Exposure is likely limited to Cisco Firepower Management Center deployments with the web-based management interface accessible to authenticated users. The provided source bundle does not specify affected versions, so teams must verify FMC inventory against Cisco guidance.

Exploitation context

The bundle states an authenticated remote attacker could send crafted SQL queries to an affected device. CISA KEV is false in the supplied data, and no cited source here confirms active exploitation.

Researcher notes

Evidence is strong for vulnerability class and impact, but incomplete for affected version ranges in this bundle. Avoid assuming public exploit activity or specific fixes beyond Cisco's advisory until the vendor data is reviewed.

Mitigation direction

  • Check Cisco's advisory for affected releases and vendor-recommended fixed software.
  • Upgrade affected Cisco FMC Software when a Cisco-supported fixed release is identified.
  • Restrict FMC web management access to trusted administration networks or VPN paths.
  • Limit FMC accounts to least privilege and remove unnecessary authenticated access.
  • Monitor FMC management activity for unexpected changes or suspicious authenticated behavior.

Validation and detection

  • Inventory all Cisco FMC instances and record software versions.
  • Compare each version against Cisco's CVE-2019-12681 advisory.
  • Confirm the management interface is not broadly reachable.
  • Review FMC user lists for unnecessary or excessive privileges.
  • Check management logs for unusual authenticated access or configuration changes.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-89: Database access and collection lookup

Injection into data stores can inform collection, data access, and exfiltration detection reviews. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
description · low confidence lookup

Database behavior lookup

The CVE wording references database injection or access, so collection and exfiltration review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2019-12681 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
High
CVSS
8.8 (3.0)
Known Exploited
No
Published

Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
8.8CVSS 3.0HighCVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H2.85.9Primary CVE score

Vulnerability scoring details

Base CVSS 3.0 score

8.8High
CVSS 3.0 vector shape for CVE-2019-12681Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
CiscoCisco Firepower Management CenterunspecifiedListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-89 · source CWE mapping

Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')

Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.