LiveActive security incident?Get immediate response
CVE Record

CVE-2019-10933: A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11),...

A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions < v5.50), Spectrum Power 7 (Corporate User Interface) (All versions <= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysismoderate

Security readout for executives and security teams

Plain-English summary

CVE-2019-10933 is a Cross-Site Scripting issue in Siemens Spectrum Power Corporate User Interface components. A victim can be affected by opening a malicious link, and they do not need to be logged in. The sources do not provide CVSS scoring or confirmed public exploitation.

Executive priority

Treat this as a targeted operational-technology web exposure issue. It does not have supplied evidence of active exploitation, but affected power-management environments should verify exposure and follow Siemens guidance promptly.

Technical view

The vulnerable web server behavior allows XSS in affected Spectrum Power 3, 4, 5, and 7 Corporate User Interface versions. The mapped weakness is CWE-80. Exploitation requires user interaction through a malicious link, but authentication to the web interface is not required.

Likely exposure

Exposure is likely limited to organizations running the affected Siemens Spectrum Power Corporate User Interface versions, especially where the interface is reachable by users through browsers or broader networks.

Exploitation context

The Siemens description says no public exploitation was known when the advisory was published. The CVE is not marked KEV in the supplied bundle. Successful exploitation requires tricking a user into accessing a malicious link.

Researcher notes

Evidence is limited to the CVE record and Siemens advisory reference in the supplied bundle. No CVSS vector, exploit details, or specific remediation text is included here, so avoid assuming impact beyond XSS via malicious-link interaction.

Mitigation direction

  • Identify all Siemens Spectrum Power Corporate User Interface deployments and versions.
  • Compare installed versions against the affected version ranges in Siemens SSA-747162.
  • Check Siemens SSA-747162 for product-specific fixes or workarounds before changes.
  • Restrict access to the Corporate User Interface to trusted networks and users.
  • Warn operators not to open unexpected links targeting internal Spectrum Power interfaces.

Validation and detection

  • Confirm whether Spectrum Power 3, 4, 5, or 7 CUI is deployed.
  • Record exact CUI product versions for each environment.
  • Verify whether unauthenticated users can reach the CUI web server.
  • Review logs for suspicious link-driven access patterns, if available.
  • Document remediation status against Siemens SSA-747162 guidance.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-80: User-session and phishing behavior lookup

Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2019-10933 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Siemens AGSpectrum Power 3 (Corporate User Interface)All versions <= v3.11Listed
Siemens AGSpectrum Power 4 (Corporate User Interface)Version v4.75Listed
Siemens AGSpectrum Power 5 (Corporate User Interface)All versions < v5.50Listed
Siemens AGSpectrum Power 7 (Corporate User Interface)All versions <= v2.20Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-80 · source CWE mapping

Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)

Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.