LiveActive security incident?Get immediate response
CVE Record

CVE-2018-8849: Medtronic N'Vision Clinician Programmer Missing Encryption of Sensitive Data

Medtronic N'Vision Clinician Programmer 8840 N'Vision Clinician Programme and 8870 N'Vision removable Application Card do not encrypt PII and PHI while at rest.

MediumCVSS 4.6Not KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

This issue means certain Medtronic N'Vision clinician systems may store patient or personal health information without encryption. The business risk is confidentiality exposure if the programmer or removable Application Card is physically accessed, lost, stolen, or mishandled. Sources do not indicate active exploitation. Exposure is most likely in healthcare or clinical support environments still using the named Medtronic N'Vision programmer or removable Application Card, especially where physical custody, servicing, storage, or disposal controls are weak. Handle as a moderate privacy and compliance risk, not an emergency remote compromise. Prioritize inventory, custody controls, and incident procedures for any remaining affected clinical assets. Mitigation focus: Review CISA and Medtronic guidance for this advisory before changing clinical workflows.; Inventory any 8840 N'Vision programmers and 8870 removable Application Cards.; Apply strict physical custody controls for programmers and removable cards..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-311: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2018-8849 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Medium
CVSS
4.6 (3.1)
Known Exploited
No
Published

Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

1CVSS vectors
0Timeline events
0ADP providers
4Source links

CVSS vector scores

1 official score

We collect every scored CVSS vector available in the official CNA and ADP containers. When more than one version is present, the table keeps the source vectors side by side instead of collapsing them into the highest score.

ScoreVersionSeverityVectorExploitImpactSource
4.6CVSS 3.1MediumCVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N0.93.6Primary CVE score

Vulnerability scoring details

Base CVSS 3.1 score

4.6Medium
CVSS 3.1 vector shape for CVE-2018-8849Attack VectorAttack ComplexityPrivileges RequiredUser InteractionScopeConfidentiality ImpactIntegrity ImpactAvailability Impact

Vector: CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Attack Vector
NetworkAdjacentLocalPhysical
Attack Complexity
LowHigh
Privileges Required
NoneLowHigh
User Interaction
NoneRequired
Scope
ChangedUnchanged
Confidentiality Impact
HighLowNone
Integrity Impact
HighLowNone
Availability Impact
HighLowNone

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
MedtronicN'Vision Clinician Programmerall versionsunaffected
Medtronic8870 N’Vision removable Application Cardall versionsunaffected
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-311 · source CWE mapping

Missing Encryption of Sensitive Data

Missing Encryption of Sensitive Data represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.