LiveActive security incident?Get immediate response
CVE Record

CVE-2018-7778: In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issu...

In Schneider Electric Evlink Charging Station versions prior to v3.2.0-12_v1, the Web Interface has an issue that may allow a remote attacker to gain administrative privileges without properly authenticating remote users.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

This flaw affects Schneider Electric Evlink Charging Station web interfaces before v3.2.0-12_v1. A remote attacker may be able to obtain administrative privileges without proper authentication. For EV charging operators, the concern is unauthorized control or configuration changes if affected management interfaces are reachable.

Executive priority

Prioritize remediation for internet-facing or broadly reachable charging station management interfaces. The available evidence does not prove exploitation, but unauthenticated administrative access can create direct operational risk.

Technical view

CVE-2018-7778 is an authentication weakness in the Evlink Charging Station Web Interface. The public record says versions before v3.2.0-12_v1 may allow a remote attacker to gain administrative privileges without properly authenticating remote users. No CVSS vector or CWE is provided in the source bundle.

Likely exposure

Exposure is most likely where Schneider Electric Evlink Charging Station web interfaces run versions before v3.2.0-12_v1, especially if management access is reachable from untrusted networks or shared operational networks.

Exploitation context

The source bundle does not cite known active exploitation, and the CVE is not listed as CISA KEV. The record still describes remote administrative privilege gain without proper authentication, so reachable affected systems should be treated as urgent.

Researcher notes

Public data is sparse: no CVSS, CWE, detailed root cause, or exploit evidence is included. Base assessment on affected version, web interface exposure, and Schneider’s advisory. Avoid assuming impact beyond administrative privilege gain described by CVE.

Mitigation direction

  • Upgrade affected Evlink Charging Stations to v3.2.0-12_v1 or later where applicable.
  • Review Schneider Electric advisory SEVD-2018-109-01 for product-specific guidance.
  • Restrict web interface access to trusted administrative networks only.
  • Remove internet exposure for charging station management interfaces.
  • Monitor for unexpected administrative changes or configuration drift.

Validation and detection

  • Inventory Evlink Charging Stations and identify web interface versions.
  • Confirm no devices run versions before v3.2.0-12_v1.
  • Verify management interfaces are not reachable from untrusted networks.
  • Review administrative accounts and recent configuration changes.
  • Check Schneider Electric guidance for any additional validation criteria.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2018-7778 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Schneider Electric SEEvlink Charging StationWeb Interface, all versions prior to v3.2.0-12_v1Listed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.