Security readout for executives and security teams
Schneider Electric U.motion Builder before v1.3.4 mishandles an update request parameter. An authenticated remote user could send a crafted request to the server. Business urgency depends on whether this building-management software is deployed, reachable, and accounts are exposed. Exposure is most likely where U.motion Builder is installed, accessible over a network, and permits authenticated users beyond tightly controlled administrators. Internet-facing or weakly managed deployments raise concern. The bundle does not identify affected CPEs or default exposure. Prioritize remediation if U.motion Builder is used in operational building environments or reachable outside a trusted admin network. Authentication lowers the bar from unauthenticated internet risk, but command-injection characterization makes exposed legacy deployments important to fix. Mitigation focus: Inventory Schneider Electric U.motion Builder deployments and versions.; Upgrade affected software to v1.3.4 or follow Schneider Electric advisory guidance.; Restrict access to trusted administrative networks only..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CVE-2018-7777 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Unknown
- CVSS
- Not scored
- Known Exploited
- No
- Published
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS and timeline data
No CVSS vectors or timeline events were available in the normalized CVE source material.
Source materials
- CVE List V5 sourceCVE List V5
- https://www.schneider-electric.com/en/download/document/SEVD-2018-095-01/CVE reference · x_refsource_CONFIRM
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.