Security readout for executives and security teams
This issue affects Schneider Electric Triconex Tricon MP model 3008 firmware 10.0 through 10.4. A memory handling flaw during system calls could let an attacker gain supervisor-level access and influence control system states. That is serious for industrial safety environments, but the provided sources do not show active exploitation or a CVSS score. Exposure is likely limited to organizations operating Schneider Electric Triconex Tricon systems with MP model 3008 firmware 10.0-10.4. Confirm through asset inventory and engineering records, not product family assumptions. Treat as high priority if affected controllers exist in production or safety-critical environments. The issue concerns privileged control over system states, so remediation should be coordinated with OT engineering and safety change processes. Mitigation focus: Identify any Tricon MP model 3008 devices running firmware 10.0-10.4.; Review Schneider Electric advisory SEVD-2017-347-01 for supported remediation.; Review CISA ICSA-18-107-02 for ICS-specific mitigation guidance..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CWE-119: Exact CWE lookup
Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.
Open ATT&CK lookupCVE-2018-7522 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Unknown
- CVSS
- Not scored
- Known Exploited
- No
- Published
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS and timeline data
No CVSS vectors or timeline events were available in the normalized CVE source material.
Source materials
- CVE List V5 sourceCVE List V5
- https://www.schneider-electric.com/en/download/document/SEVD-2017-347-01/CVE reference · x_refsource_CONFIRM
- https://ics-cert.us-cert.gov/advisories/ICSA-18-107-02CVE reference · x_refsource_MISC
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.