LiveActive security incident?Get immediate response
CVE Record

CVE-2018-7231: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3...

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the value of 'system.opkg.remove'.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

This CVE affects Schneider Electric/Pelco Sarix Professional camera firmware before the fixed vendor version. A poorly validated setting could allow command execution on the device. For executives, the business concern is loss of control over security camera infrastructure if vulnerable cameras are reachable by attackers.

Executive priority

Prioritize remediation where cameras are internet-reachable or on networks accessible to attackers. Command execution on surveillance devices can affect physical security operations, network trust, and incident response visibility.

Technical view

The issue is insufficient validation of shell metacharacters in the value of system.opkg.remove. The public record says this could allow command execution. The bundle does not provide CVSS, CWE, authentication context, or detailed attack prerequisites.

Likely exposure

Exposure is likely limited to organizations running Pelco Sarix Professional cameras on vulnerable firmware, especially where device management interfaces are reachable from untrusted networks. The bundle lists all firmware versions prior to 3.29.71 as affected, while the description also mentions prior to 3.29.67.

Exploitation context

The bundle marks KEV as false and provides no cited evidence of active exploitation. It also does not provide exploit availability or attacker prerequisites. Treat this as a serious command-execution risk without claiming observed exploitation.

Researcher notes

Evidence is incomplete. The source bundle lacks CVSS, CWE, attack vector, authentication requirements, and detailed remediation text. Version data is inconsistent between the description and affected list, so validate closure against Schneider Electric’s advisory rather than the summary alone.

Mitigation direction

  • Check Schneider Electric advisory SEVD-2018-058-01 for the authoritative fixed firmware version.
  • Upgrade affected Pelco Sarix Professional cameras to vendor-supported fixed firmware.
  • Restrict camera management interfaces to trusted administrative networks only.
  • Remove public internet exposure for affected camera services.
  • Monitor vendor guidance for any clarified remediation notes.

Validation and detection

  • Inventory Pelco Sarix Professional cameras and record firmware versions.
  • Compare installed firmware against Schneider Electric advisory SEVD-2018-058-01.
  • Verify management interfaces are not reachable from untrusted networks.
  • Review logs for unexpected administrative or package-management activity.
  • Document any version discrepancy between 3.29.67 and 3.29.71 findings.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2018-7231 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Schneider Electric SEPelco Sarix Professionalall firmware versions prior to 3.29.71Listed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.