LiveActive security incident?Get immediate response
CVE Record

CVE-2018-7229: A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3...

A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to bypass authentication and gain administrator privileges because the use of hardcoded credentials.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysishigh

Security readout for executives and security teams

Plain-English summary

This flaw affects Schneider Electric Pelco Sarix Professional camera firmware before the fixed 3.29.x release. A remote unauthenticated attacker could bypass login and obtain administrator privileges because hardcoded credentials exist. For executives, the main concern is unauthorized control of security cameras and possible pivot risk from exposed devices.

Executive priority

Treat this as high priority for any deployed Pelco Sarix Professional cameras. The available evidence indicates unauthenticated remote administrator access, which can undermine physical security monitoring. Prioritize firmware validation, upgrade planning, and network exposure reduction.

Technical view

CVE-2018-7229 is an authentication bypass in Pelco Sarix Professional caused by hardcoded credentials. The source bundle reports unauthenticated remote administrator access. Version evidence is inconsistent: the description says prior to 3.29.67, while the affected record says prior to 3.29.69.

Likely exposure

Organizations using Pelco Sarix Professional cameras with firmware earlier than the vendor-fixed 3.29.x version are the likely exposure group, especially if camera management interfaces are reachable from untrusted networks.

Exploitation context

The provided sources do not show CISA KEV listing or confirmed active exploitation. The vulnerability is still serious because the stated attack path is remote, unauthenticated, and results in administrator privileges.

Researcher notes

The source bundle lacks CVSS, CWE, detailed attack surface, and exploit-status evidence. It also contains a fixed-version discrepancy: prior to 3.29.67 in the description versus prior to 3.29.69 in affected data. Use Schneider Electric’s advisory as authoritative.

Mitigation direction

  • Check Schneider Electric advisory SEVD-2018-058-01 for the authoritative fixed firmware version.
  • Upgrade affected Pelco Sarix Professional firmware to the vendor-supported fixed release.
  • Restrict camera management interfaces to trusted administrative networks only.
  • Remove direct internet exposure for affected cameras where possible.
  • Monitor for unexpected administrator access or configuration changes.

Validation and detection

  • Inventory Pelco Sarix Professional devices and record current firmware versions.
  • Compare firmware versions against Schneider Electric advisory SEVD-2018-058-01.
  • Confirm camera management interfaces are not reachable from the public internet.
  • Review device logs for unexplained administrative activity.
  • Document any version discrepancy between 3.29.67 and 3.29.69 for vendor confirmation.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2018-7229 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Schneider Electric SEPelco Sarix Professionalall firmware versions prior to 3.29.69Listed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.