LiveActive security incident?Get immediate response
CVE Record

CVE-2018-18992: LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which...

LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

LCDS Laquis SCADA versions before 4.1.0.4150 may allow attacker-supplied input to reach server-side components without proper sanitization. The reported impact is possible remote code execution on the server, which can create serious operational risk in industrial environments. Organizations running LCDS Laquis SCADA below 4.1.0.4150 are potentially exposed, especially where the server accepts input from untrusted users or reachable network paths. Exposure cannot be determined from the CVE alone. Treat this as a high-priority industrial control system risk if Laquis SCADA is deployed. Prioritize version verification, access reduction, and vendor-guided upgrade planning because the reported impact is server code execution. Mitigation focus: Upgrade LCDS Laquis SCADA to version 4.1.0.4150 or later if available.; Review vendor and ICS-CERT guidance before applying production changes.; Restrict network access to Laquis SCADA servers to trusted management paths..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-74: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2018-18992 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
ICS-CERTLCDS Laquis SCADAAll versions prior to version 4.1.0.4150Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-74 · source CWE mapping

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')

Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.