LiveActive security incident?Get immediate response
CVE Record

CVE-2018-14799: In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWr...

In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. This can lead to buffer overflow or format string vulnerabilities.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

Philips PageWriter cardiographs before the May 2018 versions may mishandle user-entered data. In practical terms, malformed input could trigger memory corruption conditions. For healthcare organizations, the main concern is reliability and trust in cardiograph systems used in clinical workflows, not broad internet-scale exposure based on the supplied evidence. Exposure is limited to organizations operating the named Philips PageWriter cardiograph models on versions prior to May 2018. The bundle does not identify affected CPEs, internet exposure, required privileges, or attack prerequisites. Treat this as a clinical technology hygiene issue requiring verification, not an emergency based on current evidence. Prioritize inventory and vendor-supported remediation for any pre-May 2018 PageWriter cardiographs still in use. Mitigation focus: Inventory Philips PageWriter TC10, TC20, TC30, TC50, and TC70 devices.; Confirm whether each device is on a May 2018 or later version.; Review Philips product security guidance for approved updates or service actions..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-20: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2018-14799 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
3Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
PhilipsPageWriter TC10, TC20, TC30, TC50, TC70 CardiographsAll versions prior to May 2018.Listed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-20 · source CWE mapping

Improper Input Validation