LiveActive security incident?Get immediate response
CVE Record

CVE-2018-11449: A vulnerability has been identified in SCALANCE M875 (All versions).

A vulnerability has been identified in SCALANCE M875 (All versions). An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtain administrative passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysismoderate

Security readout for executives and security teams

Plain-English summary

CVE-2018-11449 affects Siemens SCALANCE M875 devices. If someone can read files on the local filesystem, they may obtain administrative passwords. This is not described as remotely exploitable by the provided sources, but exposed admin credentials can create serious operational risk.

Executive priority

Treat this as a targeted exposure issue, not an internet-scale emergency based on the provided evidence. Prioritize environments where SCALANCE M875 devices are reachable by many administrators or where credential compromise would affect operations.

Technical view

The source description states all versions of Siemens SCALANCE M875 are affected. Successful exploitation requires read access to local filesystem files and may disclose administrative user passwords. No CVSS score is provided, and the listed CWE appears inconsistent with the described password exposure.

Likely exposure

Exposure is likely limited to Siemens SCALANCE M875 deployments where an attacker, insider, compromised account, or malware can read local filesystem files.

Exploitation context

The bundle is not marked KEV, and Siemens stated that no public exploitation was known when the advisory was published. No current exploitation evidence is provided.

Researcher notes

The core prerequisite is local filesystem read access. The impact is administrative password disclosure. The source bundle lacks CVSS metrics, named fixes, and current exploitation evidence, so validation should focus on asset presence, access paths, and vendor advisory status.

Mitigation direction

  • Review Siemens SSA-977428 for vendor-approved remediation guidance.
  • Restrict local filesystem access to authorized administrative personnel only.
  • Harden administrative access paths to affected SCALANCE M875 devices.
  • Rotate administrative passwords if local file exposure is suspected.
  • Monitor vendor advisories for replacement, firmware, or configuration guidance.

Validation and detection

  • Inventory environments for Siemens SCALANCE M875 devices.
  • Confirm whether any affected devices remain in service.
  • Review access controls for local filesystem read permissions.
  • Check logs or operational records for unauthorized local access.
  • Validate remediation status against Siemens advisory SSA-977428.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-79: User-session and phishing behavior lookup

Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2018-11449 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Siemens AGSCALANCE M875SCALANCE M875 All versionsListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-79 · source CWE mapping

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.