LiveActive security incident?Get immediate response
CVE Record

CVE-2017-7970: A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Exper...

A vulnerability exists in Schneider Electric's PowerSCADA Anywhere v1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2 and Citect Anywhere version 1.0 that allows the ability to specify Arbitrary Server Target Nodes in connection requests to the Secure Gateway and Server components.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

This issue affects older Schneider Electric remote-access SCADA components. It lets connection requests specify arbitrary server target nodes when using Secure Gateway and Server components. The sources do not provide CVSS, confirmed exploitation, or detailed impact, so urgency depends on whether these products are deployed and reachable. Exposure is limited to environments running the named Schneider Electric versions, especially where Secure Gateway or Server components are accessible across less-trusted networks. Confirm product presence before prioritizing broadly. Prioritize discovery first. If affected components are present in operational technology networks or exposed across trust boundaries, treat remediation as time-sensitive despite incomplete public severity data. Mitigation focus: Check Schneider Electric advisories for supported fixes or upgrade guidance.; Inventory PowerSCADA Anywhere and Citect Anywhere deployments and versions.; Restrict Secure Gateway and Server component access to trusted management networks..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2017-7970 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
Schneider Electric SEPowerSCADA AnywhereVersion 1.0 redistributed with PowerSCADA Expert v8.1 and PowerSCADA Expert v8.2Listed
Schneider Electric SECitect Anywhereversion 1.0Listed
Weakness

CWE details

No CWE listed