LiveActive security incident?Get immediate response
CVE Record

CVE-2017-6032: A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol.

A Violation of Secure Design Principles issue was discovered in Schneider Electric Modicon Modbus Protocol. The Modicon Modbus protocol has a session-related weakness making it susceptible to brute-force attacks.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

This CVE describes a design weakness in Schneider Electric Modicon Modbus Protocol that can make session handling vulnerable to brute-force attempts. The sources do not provide CVSS, a confirmed patch, or evidence of active exploitation. Business urgency depends on whether this protocol is present in reachable operational technology environments. Likely exposure is limited to environments using Schneider Electric Modicon Modbus Protocol, especially OT networks where access is not tightly controlled. The bundle does not identify specific affected device models or versions. Treat this as an OT exposure review item rather than an emergency unless reachable affected systems are found. Prioritize environments where Modbus access crosses trust boundaries or remote access paths. Mitigation focus: Review CISA ICSA-17-101-01 and Schneider guidance for affected deployments.; Inventory systems using Schneider Electric Modicon Modbus Protocol.; Restrict protocol access to trusted OT management paths only..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · low confidence lookup

CWE-657: Exact CWE lookup

Use the exact CWE identifier as the starting point before reviewing related ATT&CK behavior. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2017-6032 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aSchneider Electric Modicon Modbus ProtocolSchneider Electric Modicon Modbus ProtocolListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-657 · source CWE mapping

Violation of Secure Design Principles

Violation of Secure Design Principles represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.