LiveActive security incident?Get immediate response
CVE Record

CVE-2017-6018: An open redirect issue was discovered in B.

An open redirect issue was discovered in B. Braun Medical SpaceCom module, which is integrated into the SpaceStation docking station: SpaceStation with SpaceCom module (integrated as part number 8713142U), software versions prior to Version 012U000040, and SpaceStation (part number 8713140U) with installed SpaceCom module (part number 8713160U), software versions prior to Version 012U000040. The web server of the affected product accepts untrusted input which could allow attackers to redirect the request to an unintended URL contained within untrusted input.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysismoderate

Security readout for executives and security teams

Plain-English summary

CVE-2017-6018 is an open redirect in the B. Braun Medical SpaceCom web server used with SpaceStation docking stations. An attacker could craft a link that sends a user to an unintended URL. The source bundle does not show device takeover or patient-impact evidence.

Executive priority

Treat as a targeted medical-device hygiene issue, not an emergency based on available evidence. Prioritize inventory and vendor-guided update planning for affected SpaceCom deployments.

Technical view

Affected SpaceCom web server versions before 012U000040 accept untrusted input for redirects, matching CWE-601. Impact is primarily trust abuse, phishing, or navigation to attacker-controlled sites through a legitimate device interface. The bundle provides no CVSS score and no proof of active exploitation.

Likely exposure

Exposure is limited to B. Braun Medical SpaceCom modules integrated in or installed with specified SpaceStation docking station part numbers, running software before Version 012U000040.

Exploitation context

The CVE is not in KEV, and the provided sources do not cite active exploitation. Exploitation would require a reachable affected web server and a user or workflow that follows a crafted redirect.

Researcher notes

Evidence is narrow: affected products, version threshold, CWE-601, and redirect behavior are documented, but severity, CVSS metrics, exploit maturity, and detailed remediation are not included in the bundle.

Mitigation direction

  • Inventory SpaceStation systems with SpaceCom modules and recorded part numbers.
  • Compare SpaceCom software versions against Version 012U000040.
  • Use B. Braun or ICS-CERT guidance for approved update or remediation steps.
  • Limit SpaceCom web server access to trusted clinical engineering networks where operationally feasible.

Validation and detection

  • Confirm whether part numbers 8713142U, 8713140U, or 8713160U are present.
  • Record the installed SpaceCom software version for each device.
  • Check whether any affected web interfaces are reachable from untrusted networks.
  • Review logs or proxy data for suspicious redirect patterns if available.
Prepared
Confidence
medium
Sources
3

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-601: User-session and phishing behavior lookup

Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2017-6018 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aB. Braun Medical SpaceComB. Braun Medical SpaceComListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-601 · source CWE mapping

URL Redirection to Untrusted Site ('Open Redirect')

URL Redirection to Untrusted Site ('Open Redirect') represents a recurring weakness pattern that can create exploitable paths when design, validation, or implementation controls are missing.