LiveActive security incident?Get immediate response
CVE Record

CVE-2017-5167: An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter.

An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

This CVE describes a BINOM3 electric power quality meter where users cannot change their own passwords. That creates an operational security problem: credentials may remain unchanged after personnel changes, suspected compromise, or routine rotation needs. The source bundle does not provide severity scoring, a patch version, or evidence of active exploitation. Exposure is limited to organizations that deployed BINOM3 Electric Power Quality Meters. Risk depends on whether the device’s management interface is reachable by users, administrators, vendor support, or network segments where credentials could be misused. Prioritize this where BINOM3 meters support critical operations or have broad management access. The issue is not proven actively exploited in the bundle, but weak credential lifecycle control can increase business risk during staff turnover or credential incidents. Mitigation focus: Check the ICS-CERT advisory and vendor guidance for supported remediation.; Inventory BINOM3 meters and identify who can authenticate to them.; Restrict management access to only required trusted networks and administrators..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2017-5167 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aBINOM3 Electric Power Quality MeterBINOM3 Electric Power Quality MeterListed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.