LiveActive security incident?Get immediate response
CVE Record

CVE-2017-5165: An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter.

An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

CVE-2017-5165 affects the BINOM3 Electric Power Quality Meter. The device web interface lacks CSRF protection, so an authenticated user could be tricked into triggering unauthorized configuration changes. The bundle does not provide severity scoring, patch status, or confirmed exploitation. Exposure is limited to environments using BINOM3 Electric Power Quality Meters with reachable management interfaces. Risk is higher where administrators access device management from general-purpose browsers or untrusted networks. Prioritize assessment where these meters support operational power monitoring or control workflows. Business urgency depends on deployment presence and management interface exposure, because unauthorized configuration changes could affect device integrity. Mitigation focus: Review the ICS-CERT advisory and vendor guidance for supported fixes or compensating controls.; Restrict device management access to trusted administration networks.; Avoid browsing untrusted sites while authenticated to the device interface..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

description · low confidence lookup

Credential and access behavior lookup

The CVE wording references authentication or credential exposure, so valid-account and credential-access review may help. This is a Glexia inferred lookup path, not an official MITRE, ATT&CK, or CVE Program mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2017-5165 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aBINOM3 Electric Power Quality MeterBINOM3 Electric Power Quality MeterListed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.