CVE-2017-12722: An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump,...

An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the communications module to crash. Smiths Medical assesses that the crash of the communications module would not impact the operation of the therapeutic module.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

CVE-2017-12722 affects Smiths Medical Medfusion 4000 wireless syringe infusion pumps running versions 1.1, 1.5, and 1.6. A software component can read memory outside its expected bounds and crash the communications module. Smiths Medical assessed that therapy delivery is not impacted, but loss of communications can still disrupt monitoring, workflows, or device management. Exposure is limited to organizations using Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pumps on versions 1.1, 1.5, or 1.6. Risk is higher where pump communications are reachable from broad clinical, corporate, or wireless networks. Prioritize this for healthcare environments with Medfusion 4000 deployments, especially if pumps depend on wireless communications. The cited impact is not therapy interruption, but communications loss in clinical devices can create operational and monitoring risk. Mitigation focus: Inventory Medfusion 4000 pumps and firmware versions.; Check Smiths Medical and CISA guidance for approved remediation.; Limit pump communications to trusted clinical networks..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cve · low confidence lookup

CVE-2017-12722 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Source materials

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aSmiths Medical Medfusion 4000 Wireless Syringe Infusion PumpSmiths Medical Medfusion 4000 Wireless Syringe Infusion PumpListed
Weakness

CWE details

No CWE listed

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.