CVE-2017-12722 affects Smiths Medical Medfusion 4000 wireless syringe infusion pumps running versions 1.1, 1.5, and 1.6. A software component can read memory outside its expected bounds and crash the communications module. Smiths Medical assessed that therapy delivery is not impacted, but loss of communications can still disrupt monitoring, workflows, or device management. Exposure is limited to organizations using Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pumps on versions 1.1, 1.5, or 1.6. Risk is higher where pump communications are reachable from broad clinical, corporate, or wireless networks. Prioritize this for healthcare environments with Medfusion 4000 deployments, especially if pumps depend on wireless communications. The cited impact is not therapy interruption, but communications loss in clinical devices can create operational and monitoring risk. Mitigation focus: Inventory Medfusion 4000 pumps and firmware versions.; Check Smiths Medical and CISA guidance for approved remediation.; Limit pump communications to trusted clinical networks..
Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.
Conservative CVE-to-ATT&CK context
These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.
ATT&CK lookup starting points
Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.
CVE-2017-12722 mapping review
Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.
Open ATT&CK lookup- Severity
- Unknown
- CVSS
- Not scored
- Known Exploited
- No
- Published
CNA and ADP enrichment extracted from CVE v5
These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.
CVSS and timeline data
No CVSS vectors or timeline events were available in the normalized CVE source material.
Source materials
- CVE List V5 sourceCVE List V5
- https://ics-cert.us-cert.gov/advisories/ICSMA-17-250-02ACVE reference · x_refsource_MISC
Products and packages named in the record
CWE details
CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.