LiveActive security incident?Get immediate response
CVE Record

CVE-2017-12307: A vulnerability in the web framework of Cisco Small Business Managed Switches software could allow an unaut...

A vulnerability in the web framework of Cisco Small Business Managed Switches software could allow an unauthenticated, remote attacker to conduct a reflected cross-site scripting (XSS) attack against a user of the web interface of an affected system. The vulnerability is due to insufficient input validation of parameters that are passed to the web server of the affected system. An attacker could exploit this vulnerability by convincing a user to follow a malicious link or by intercepting and injecting code into a user request. A successful exploit could allow the attacker to execute arbitrary script code in the context of the affected web interface or allow the attacker to access sensitive browser-based information. This vulnerability affects the following Cisco Small Business 300 and 500 Series Managed Switches: Cisco Small Business 300 Series Managed Switches, Cisco Small Business 500 Series Stackable Managed Switches, Cisco 350 Series Managed Switches, Cisco 350X Series Stackable Managed Switches, Cisco 550X Series Stackable Managed Switches, Cisco ESW2 Series Advanced Switches. Cisco Bug IDs: CSCvg24637.

UnknownCVSS not scoredNot KEV-listedUpdated
Glexia's TakeAutomated analysis

Security readout for executives and security teams

CVE-2017-12307 is a reflected XSS issue in the web interface of several Cisco Small Business managed switch families. An attacker must trick a user or interfere with a request, but successful exploitation could run script in the switch management session and expose browser-held information. Exposure is most relevant where affected Cisco Small Business switch web interfaces are reachable by administrators, especially from shared, untrusted, or poorly segmented networks. Devices with management access limited to trusted admin paths have lower practical risk. Treat this as a targeted management-plane risk, not a broad internet worm scenario. Prioritize affected switches that administrators manage over reachable web interfaces or from untrusted networks. Mitigation focus: Review Cisco advisory for fixed software and upgrade guidance.; Restrict switch web management to trusted administrator networks.; Disable unnecessary remote access to management interfaces where possible..

Prepared

Generated from the cited source records. This long-tail analysis has not been individually reviewed by a named human.

Potential ATT&CK relevance

Conservative CVE-to-ATT&CK context

These mappings and lookup hints may be relevant to the vulnerability behavior, CWE, affected product, or exposure path. Glexia-inferred context is not an official MITRE, ATT&CK, CWE, or CVE Program mapping.

ATT&CK lookup starting points

Use these exact CWE pages and searches to review the Glexia ATT&CK library from this CVE's weakness and description context.

cwe · medium confidence lookup

CWE-79: User-session and phishing behavior lookup

Client-side and session-facing weaknesses should be reviewed alongside initial-access and user-execution behaviors. Open the exact CWE lookup page first, then review the ATT&CK searches from that MITRE weakness context. This is a Glexia lookup hint, not an official ATT&CK mapping.

Open ATT&CK lookup
cve · low confidence lookup

CVE-2017-12307 mapping review

Open the CVE-to-ATT&CK bridge for reviewed, inferred, or future official mappings tied to this CVE.

Open ATT&CK lookup
Vulnerability profileCVE Program record
Severity
Unknown
CVSS
Not scored
Known Exploited
No
Published
Official CVE source material

CNA and ADP enrichment extracted from CVE v5

These fields come from the CVE record and ADP containers, not from Glexia's Take. They preserve time-varying source decisions such as CISA SSVC, KEV status, CVSS metrics, and provider references.

0CVSS vectors
0Timeline events
0ADP providers
2Source links

CVSS and timeline data

No CVSS vectors or timeline events were available in the normalized CVE source material.

Affected products

Products and packages named in the record

VendorProductVersion / packageStatus
n/aCisco Small Business 300 and 500 Series Managed SwitchesCisco Small Business 300 and 500 Series Managed SwitchesListed
Weakness

CWE details

CWE links open Glexia weakness intelligence pages with official CWE context, developer remediation guidance, and related CVE mappings.

CWE-79 · source CWE mapping

Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')